Assessment of Extubation Readiness Using Spontaneous Breathing Trials in Extremely Preterm Neonates

2019· article· en· W2996614924 sur OpenAlexaff
Wissam Shalish, Lara J. Kanbar, Lajos Kovács, Sanjay Chawla, Martin Keszler, Smita Rao, Samantha Latremouille, Doina Precup, Karen A. Brown, Robert E. Kearney, Guilherme SantʼAnna

Notice bibliographique

RevueJAMA Pediatrics · 2019
Typearticle
Langueen
DomaineMedicine
ThématiqueNeonatal Respiratory Health Research
Établissements canadiensJewish General HospitalMontreal Children's HospitalMcGill University
Organismes subventionnairesnon disponible
Mots-clésMedicineInterquartile rangeContinuous positive airway pressureGestational ageNeonatal intensive care unitApneaClinical trialCardiorespiratory fitnessIntensive careMechanical ventilationProspective cohort studyAnesthesiaPediatricsObstructive sleep apneaIntensive care medicineSurgeryPregnancyInternal medicine

Résumé

récupéré en direct d'OpenAlex

Importance: Spontaneous breathing trials (SBTs) are used to determine extubation readiness in extremely preterm neonates (gestational age ≤28 weeks), but these trials rely on empirical combinations of clinical events during endotracheal continuous positive airway pressure (ET-CPAP). Objectives: To describe clinical events during ET-CPAP and to assess accuracy of comprehensive clinical event combinations in predicting successful extubation compared with clinical judgment alone. Design, Setting, and Participants: This multicenter diagnostic study used data from 259 neonates seen at 5 neonatal intensive care units from the prospective Automated Prediction of Extubation Readiness (APEX) study from September 1, 2013, through August 31, 2018. Neonates with birth weight less than 1250 g who required mechanical ventilation were eligible. Neonates deemed to be ready for extubation and who underwent ET-CPAP before extubation were included. Interventions: In the APEX study, cardiorespiratory signals were recorded during 5-minute ET-CPAP, and signs of clinical instability were monitored. Main Outcomes and Measures: Four clinical events were documented during ET-CPAP: apnea requiring stimulation, presence and cumulative durations of bradycardia and desaturation, and increased supplemental oxygen. Clinical event occurrence was assessed and compared between extubation pass and fail (defined as reintubation within 7 days). An automated algorithm was developed to generate SBT definitions using all clinical event combinations and to compute diagnostic accuracies of an SBT in predicting extubation success. Results: Of 259 neonates (139 [54%] male) with a median gestational age of 26.1 weeks (interquartile range [IQR], 24.9-27.4 weeks) and median birth weight of 830 g (IQR, 690-1019 g), 147 (57%) had at least 1 clinical event during ET-CPAP. Apneas occurred in 10% (26 of 259) of neonates, bradycardias in 19% (48), desaturations in 53% (138), and increased oxygen needs in 41% (107). Neonates with successful extubation (71% [184 of 259]) had significantly fewer clinical events (51% [93 of 184] vs 72% [54 of 75], P = .002), shorter cumulative bradycardia duration (median, 0 seconds [IQR, 0 seconds] vs 0 seconds [IQR, 0-9 seconds], P < .001), shorter cumulative desaturation duration (median, 0 seconds [IQR, 0-59 seconds] vs 25 seconds [IQR, 0-90 seconds], P = .003), and less increase in oxygen (median, 0% [IQR, 0%-6%] vs 5% [0%-18%], P < .001) compared with neonates with failed extubation. In total, 41 602 SBT definitions were generated, demonstrating sensitivities of 51% to 100% (median, 96%) and specificities of 0% to 72% (median, 22%). Youden indices for all SBTs ranged from 0 to 0.32 (median, 0.17), suggesting low accuracy. The SBT with highest Youden index defined SBT pass as having no apnea (with desaturation requiring stimulation) or increase in oxygen requirements by 15% from baseline and predicted extubation success with a sensitivity of 93% and a specificity of 39%. Conclusions and Relevance: The findings suggest that extremely preterm neonates commonly show signs of clinical instability during ET-CPAP and that the accuracy of multiple clinical event combinations to define SBTs is low. Thus, SBTs may provide little added value in the assessment of extubation readiness.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,005
score de la tête « metaresearch » (Gemma)0,004
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Observationnel · Signal consensuel: Observationnel
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,247
Score d'incertitude au seuil0,615

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0050,004
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0010,000
Bibliométrie0,0010,001
Études des sciences et des technologies0,0000,000
Communication savante0,0000,000
Science ouverte0,0000,000
Intégrité de la recherche0,0000,000
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,094
Tête enseignante GPT0,423
Écart entre enseignants0,329 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeObservationnel
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations59
Publié2019
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueJAMA PediatricsMême sujetNeonatal Respiratory Health ResearchTravaux en français237 207