Mid-term results of total hip arthroplasty using a novel uncemented short femoral stem with metaphyso-diaphyseal fixation
Notice bibliographique
Résumé
PURPOSE: Short stems were developed with the promise of providing easier implantation, facilitating revision, reducing thigh pain and proximal stress shielding. The aim of this study is to present the mid-term clinical results of a titanium short stem with modular neck. METHODS: This is a prospective case series of 144 THAs performed on a series of 131 patients using the PROFEMUR Preserve Femoral Stem (MicroPort Orthopedics, Arlington, TN, USA). 2 surgeons, operated on the patients using a mini-posterior approach. The primary outcomes evaluated were stem revision for aseptic loosening and all-cause stem revision. Clinical and radiographic outcomes were also assessed. RESULTS: Of the 144 THAs, there were 43 males and 101 females, with an average age of 61 (range 22-92) years at surgery. After a mean of 78 (range 53-87) months follow-up, there were 2 (1.5%) femoral implant revisions; 1 for early femoral periprosthetic fracture and 1 for fatigue failure of the modular femoral neck. There were no cases of stem aseptic loosening and radiographic analysis demonstrated no cases of stem migration. The mean UCLA activity, WOMAC and Fogotten Joint scores were respectively 6.1, 10.7 and 86.6. 70% of prosthetic hips were observed as having no restriction and 99.2% of patients were satisfied with their THA. CONCLUSIONS: This short modular stem produced satisfactory clinical and radiological results at mid-term, with 98.5% implant survival for any cause of stem revision and no revisions for aseptic loosening. Long-term results are required to further evaluate the stem's promising early results.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».