A145 A SUBMUCOSAL FLUID CUSHION PREVENTS MUSCLE LAYER DAMAGE DURING ARGON PLASMA COAGULATION
Notice bibliographique
Résumé
Abstract Background Thermal damage to the muscle layer of the gastrointestinal wall can occur during mucosal application of argon plasma coagulation (APC). This injury may be mitigated by creating a fluid cushion within the submucosal layer that physically separates the mucosa from the muscle layer and suppresses unwanted tissue temperature elevation. This in turn protects the muscle layer from thermal damage. The coagulative threshold of muscle proteins is known to be about 60°C, but there are no published systematic assessments of the minimum injection volume needed nor the ideal injectate to prevent thermal damage to the muscle layer during mucosal APC ablation. Aims Our aims were, firstly, to measure the final temperature inside the fluid cushion after mucosal ablation with APC and then to determine any differences in the final temperature between various injectable solutions. Secondly, we sought to determine the minimum volume of injectate required to protect the muscle layer from thermal damage. Methods All experiments were performed in an ex-vivo porcine gastrointestinal tract model. Five different fluids (normal saline, Glyceol, Gelafundin, Voluven and Eleview) of different volumes (range 0 - 5mL) were injected into the submucosa of the esophagus, stomach (fundus) and rectum to create a fluid cushion. APC was applied to the mucosa for a fixed duration (3s) at different power settings (ranging from 30 - 120W). Immediately after APC treatment, the final temperature was measured by placing a contact thermometer inside the fluid cushion, just on top of the muscle layer. Results There was no significant difference in the temperature measured at the surface of the muscle layer between elevation with normal saline, Glyceol, Gelafundin, Voluven and Eleview at all 3 tissue locations at equal injection volumes and power settings. The experiments showed that the temperature rose for each injectate with heightened power settings but also decreased with increasing volume of injected fluid. The minimum amount of fluid needed to protect the muscle layer from thermal damage was 2mL for the esophagus, stomach and rectum in the case of a power setting between 30 to 90W and 3mL in the case of 90 to 120W. Conclusions Normal saline and four commercially available submucosal injectates possess similar thermoregulatory effects as an insulator of the muscle layer during APC treatment. As opposed to the choice of injectate or anatomic location treated, the volume of fluid injected is the main determinant of the final temperature at the level of the muscularis propria. To reduce the likelihood of thermal damage to deeper layers of the GI tract when APC is applied, a minimum injection volume of 2mL is recommended if <90W of power is utilized. Funding Agencies None
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».