Cascade Terminal Sliding Mode Control of a Deployable Cable Driven Robot
Notice bibliographique
Résumé
Most control systems used for cable-driven parallel manipulators employ a simple inner control loop for controlling the driving force of the actuators. By this means the effects of some nonlinear uncertainties of the actuator and power transmission systems are significantly reduced, and in turn, this helps the outer user-specified position control loop to perform more accurately. However, this positive impact on performance relies on non achievable assumptions that the inner control loop is fast and accurate enough, and its dynamics can be totally ignored. The main contribution of this paper is to analyze the stability of the system as a whole, considering both inner and outer loop controllers. The outer loop controller proposed in here is a finite time robust sliding mode whose stability is analyzed through the Lyapunov direct method. A deployable cable-driven parallel robot, as the case study, is also considered in this paper, which is characterized by several intrinsic kinematic and dynamic uncertainties. Finally, the performance and effectiveness of the proposed robust controller is evaluated through some simulations and experiments in order to verify the effectiveness and the characteristics of the cascade controller structure in practice.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».