The Effect of Carbetocin Dose on Transmural Dispersion of Myocardial Repolarization in Healthy Parturients Scheduled for Elective Cesarean Delivery Under Spinal Anesthesia: A Prospective, Randomized Clinical Trial
Notice bibliographique
Résumé
BACKGROUND: QT interval prolongation is associated with torsade de pointes but remains a poor predictor of drug torsadogenicity. Increased transmural dispersion of myocardial repolarization (TDR), measured as the time interval between the peak and end of the T wave (Tp-e), is a more reliable predictor. Carbetocin is recommended as an uterotonic in patients undergoing cesarean delivery (CD), but its effect on Tp-e is unknown. We evaluated the effect of carbetocin dose on Tp-e and Bazett-corrected QT intervals (QTc) during elective CD under spinal anesthesia. METHODS: On patient consent, 50 healthy parturients undergoing elective CD with a standardized spinal anesthetic and phenylephrine infusion were randomized to receive an intravenous (IV) bolus of carbetocin 50 µg (C50) or 100 µg (C100) via an infusion pump over 1 minute. A 12-lead electrocardiogram (ECG) was obtained at baseline, 5 minutes after spinal anesthesia, then 5 and 10 minutes after carbetocin administration. A cardiologist blinded to group and timing of ECGs measured QTc and Tp-e using Emori's criteria. Primary outcome was the change in Tp-e at 5 minutes after carbetocin administration between the C50 and C100 groups and within each group compared to baseline values. Secondary outcomes included occurrence of arrhythmias, changes in QTc at 5 and 10 minutes after carbetocin, changes in both QTc and Tp-e after spinal anesthesia compared to baseline between and within groups. RESULTS: Data from 41 parturients with a mean (standard deviation [SD]) age of 39.0 (0.7) years and weight of 75.0 (12.0) kg were analyzed. Between groups, at 5 minutes after carbetocin administration, Tp-e in C100 was 4.1 milliseconds longer compared to C50 (95% confidence interval [CI], 0.8-7.5; P = .01). Within groups, at 5 minutes after carbetocin administration, C50 did not significantly increase Tp-e compared to baseline (mean difference [MD] 1.9 milliseconds; 95% CI, -0.95 to 4.81 milliseconds; P = .42) but C100 did (MD 5.1 milliseconds; 95% CI, 2.1-8.1; P = .003). QTc increased significantly within C50 and C100 groups at 5 and 10 minutes after carbetocin administration (all P < .001), with no between-group differences. There were no arrhythmias. CONCLUSIONS: Tp-e was unaffected by C50 IV given after CD in healthy parturients under spinal anesthesia, but minimally prolonged by C100. The increase in QTc after carbetocin administration was statistically significant, but with no apparent dose-dependent effect. The minimal Tp-e prolongation at the higher dose is unlikely to have any clinically significant impact on TDR and therefore the risk of inducing torsade de pointes is low.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,002 | 0,004 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,001 |
| Méta-épidémiologie (sens large) | 0,002 | 0,002 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,001 |
| Communication savante | 0,001 | 0,001 |
| Science ouverte | 0,001 | 0,000 |
| Intégrité de la recherche | 0,002 | 0,002 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,004 | 0,001 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».