Water Tree Detection in Medium Voltage XLPE Cables
Notice bibliographique
Résumé
During the period of 1993-1995 Manitoba Hydro investigated the claim by a service provider that water trees could be detected and located in service aged medium voltage XLPE cables by means of time domain reflectometry (TDR) following conditioning of the cable dielectric with direct voltage. In order to avoid subsequent short time in-service failures, it was necessary to limit the conditioning voltage to 0.5 per-unit. With this restriction, no conditioning related surge impedance anomalies were found in cable that subsequently was determined as containing substantial vented water trees. However, it was established that the measurement of leakage current at 0.5 per-unit negative polarity direct voltage did correlate with the magnitude of subsequent 0.1 Hz breakdown voltage. Beginning in 2014 Manitoba Hydro has been assessing service aged medium voltage XLPE cables using Tangent Delta measurements at 0.1 Hz voltages in accordance with IEEE Std 400.2. However, the notion that water tress can be detected and located as a result of conditioning with direct voltage is still of interest as is indicated by publications that have appeared in the literature in recent years, but the related conditioning utilizes direct voltages in excess of 0.5 per-unit.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,001 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».