MétaCan
Menu
Retour à la cohorte
Enregistrement W3015817074 · doi:10.1002/ehf2.12645

Improved Cardiac and Venous Pressures During Hospital Stay in Patients with Acute Heart Failure: An Echocardiography and Biomarkers Study

2020· article· en· W3015817074 sur OpenAlexaff
Eiichi Akiyama, Raphaël Cinotti, Kamilė Čerlinskaitė‐Bajorė, Lucas Van Aelst, Mattia Arrigo, Rui Plácido, Tahar Chouihed, Nicolas Girerd, Faı̈ez Zannad, Patrick Rossignol, Marc Badoz, Jean‐Marie Launay, Étienne Gayat, Alain Cohen‐Solal, Carolyn S.P. Lam, Jeffrey M. Testani, Wilfried Müllens, Gad Cotter, Marie‐France Seronde, Alexandre Mebazaa

Notice bibliographique

RevueESC Heart Failure · 2020
Typearticle
Langueen
DomaineMedicine
ThématiqueCardiovascular Function and Risk Factors
Établissements canadiensHotel Dieu Hospital
Organismes subventionnairesFP7 HealthNational Center for Advancing Translational SciencesJapan Heart FoundationAgence Nationale de la RechercheTranslation Centre for the Bodies of the European UnionEuropean CommissionEuropean Society of CardiologyInternational Society for Heart and Lung Transplantation
Mots-clésMedicineHeart failureInternal medicineCardiologyEjection fractionNatriuretic peptideDiastoleInferior vena cavaCentral venous pressureVenous bloodHeart failure with preserved ejection fractionDiastolic heart failureBlood pressureHeart rate

Résumé

récupéré en direct d'OpenAlex

Abstract Aims Changes in echocardiographic parameters and biomarkers of cardiac and venous pressures or estimated plasma volume during hospitalization associated with decongestive treatments in acute heart failure (AHF) patients with either preserved left ventricular ejection fraction (LVEF) (HFPEF) or reduced LVEF (HFREF) are poorly assessed. Methods and results From the metabolic road to diastolic heart failure: diastolic heart failure (MEDIA-DHF) study, 111 patients were included in this substudy: 77 AHF (43 HFPEF and 34 HFREF) and 34 non-cardiac dyspnea patients. Echocardiographic measurements and blood samples were obtained within 4 h of presentation at the emergency department and before hospital discharge. In AHF patients, echocardiographic indices of cardiac and venous pressures, including inferior vena cava diameter [from 22 (16–24) mm to 13 (11–18) mm, P = 0.009], its respiratory variability [from 32 (8–44) % to 43 (29–70) %, P = 0.04], medial E/e' [from 21.1 (15.8–29.6) to 16.6 (11.7–24.3), P = 0.004], and E wave deceleration time [from 129 (105–156) ms to 166 (128–203) ms, P = 0.003], improved during hospitalization, similarly in HFPEF and HFREF patients. By contrast, no changes were seen in non-cardiac dyspnea patients. In AHF patients, all plasma biomarkers of cardiac and venous pressures, namely B-type natriuretic peptide [from 935 (514–2037) pg/mL to 308 (183–609) pg/mL, P < 0.001], mid-regional pro-atrial natriuretic peptide [from 449 (274–653) pmol/L to 366 (242–549) pmol/L, P < 0.001], and soluble CD-146 levels [from 528 (406–654) ng/mL to 450 (374–529) ng/mL, P = 0.003], significantly decreased during hospitalization, similarly in HFPEF and HFREF patients. Echocardiographic parameters of cardiac chamber dimensions [left ventricular end-diastolic volume: from 120 (76–140) mL to 118 (95–176) mL, P = 0.23] and cardiac index [from 2.1 (1.6–2.6) mL/min/m2 to 1.9 (1.4–2.4) mL/min/m2, P = 0.55] were unchanged in AHF patients, except tricuspid annular plane systolic excursion (TAPSE) that improved during hospitalization [from 16 (15–19) mm to 19 (17–21) mm, P = 0.04]. Estimated plasma volume increased in both AHF [from 4.8 (4.2–5.6) to 5.1 (4.4–5.8), P = 0.03] and non-cardiac dyspnea patients (P = 0.01). Serum creatinine [from 1.18 (0.90–1.53) to 1.19 (0.86–1.70) mg/dL, P = 0.89] and creatinine-based estimated glomerular filtration rate [from 59 (40–75) mL/min/1.73m2 to 56 (38–73) mL/min/1.73m2, P = 0.09] were similar, while plasma cystatin C [from 1.50 (1.20–2.27) mg/L to 1.78 (1.33–2.59) mg/L, P < 0.001] and neutrophil gelatinase associated lipocalin (NGAL) [from 127 (95–260) ng/mL to 167 (104–263) ng/mL, P = 0.004] increased during hospitalization in AHF. Conclusions Echocardiographic parameters and plasma biomarkers of cardiac and venous pressures improved during AHF hospitalization in both acute HFPEF and HFREF patients, while cardiac chamber dimensions, cardiac output, and estimated plasma volume showed minimal changes.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,000
score de la tête « metaresearch » (Gemma)0,000
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Observationnel · Signal consensuel: Observationnel
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,013
Score d'incertitude au seuil0,936

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0000,000
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0010,000
Bibliométrie0,0000,000
Études des sciences et des technologies0,0000,000
Communication savante0,0000,000
Science ouverte0,0000,000
Intégrité de la recherche0,0000,000
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,003
Tête enseignante GPT0,198
Écart entre enseignants0,195 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeObservationnel
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations13
Publié2020
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueESC Heart FailureMême sujetCardiovascular Function and Risk FactorsTravaux en français237 207