A Three-Phase Single-Sensor-Based Cuk-Derived PFC Converter With Reduced Number of Components for More Electric Aircraft
Notice bibliographique
Résumé
A new three-phase Cuk-derived power factor corrected (PFC) converter with only three switches for more electric aircraft is presented. The proposed converter benefits limited components for its operation, and only one semiconductor from each phase is in the current conduction path throughout the converter operation that substantially reduces the conduction losses leading to high efficiency and low converter thermal management. Further, the control effort required for converter operation is very less as all the three switches are driven by one gate signal. The converter output inductors are designed for discontinuous current operation for the entire converter power range to realize natural PFC at ac power source. The converter control is very simple, economical, and reliable since only one sensor is required for implementation. A detailed discussion on the converter steady-state operation for one switching cycle is presented. The converter small-signal model and the design expressions are derived to ease the converter control and the design. Further, the feasibility of the proposed scheme and the design are validated with the experimental results from a 2-kW laboratory prototype.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».