MétaCan
Menu
Retour à la cohorte
Enregistrement W3021536489 · doi:10.1186/s12968-020-00613-3

T1 mapping performance and measurement repeatability: results from the multi-national T1 mapping standardization phantom program (T1MES)

2020· article· en· W3021536489 sur OpenAlexaff
Gabriella Captur, Abhiyan Bhandari, Rüdiger Brühl, Bernd Ittermann, Kathryn E. Keenan, Yang Ye, Richard J. Eames, Giulia Benedetti, Camilla Torlasco, Lewis Ricketts, Redha Boubertakh, Nasri Fatih, John P. Greenwood, Leonie E. Paulis, Chris Lawton, Chiara Bucciarelli‐Ducci, Hildo J. Lamb, Richard P. Steeds, Steve Leung, Colin Berry, Sinitsyn Valentin, Andrew Flett, Charlotte de Lange, Francesco De Cobelli, Magalie Viallon, Pierre Croisille, David Higgins, Andreas Greiser, Wenjie Pang, Christian Hamilton‐Craig, W. Strugnell, Tom Dresselaers, Andrea Barison, Dana Dawson, Andrew J. Taylor, François‐Pierre Mongeon, Sven Plein, Daniel Messroghli, Mouaz H. Al‐Mallah, Stuart M. Grieve, Massimo Lombardi, Jihye Jang, Michael Salerno, Nish Chaturvedi, Peter Kellman, David A. Bluemke, Reza Nezafat, Peter Gatehouse, James Moon

Notice bibliographique

RevueJournal of Cardiovascular Magnetic Resonance · 2020
Typearticle
Langueen
DomaineMedicine
ThématiqueAdvanced MRI Techniques and Applications
Établissements canadiensUniversité de MontréalMontreal Heart Institute
Organismes subventionnairesEuropean Association of Cardiovascular ImagingSiemens HealthineersUniversity College LondonBritish Heart FoundationMedical Research CouncilBarts CharityEuropean Society of CardiologyNational Institute for Health and Care Research
Mots-clésRepeatabilityImaging phantomQuality assuranceNuclear medicineMedicineStandardizationCoefficient of variationReproducibilityBiomedical engineeringMedical physicsMathematicsStatisticsComputer sciencePathology

Résumé

récupéré en direct d'OpenAlex

The T 1 Mapping and Extracellular volume (ECV) Standardization (T1MES) program explored T 1 mapping quality assurance using a purpose-developed phantom with Food and Drug Administration (FDA) and Conformité Européenne (CE) regulatory clearance. We report T 1 measurement repeatability across centers describing sequence, magnet, and vendor performance. Phantoms batch-manufactured in August 2015 underwent 2 years of structural imaging, B 0 and B 1 , and “reference” slow T 1 testing. Temperature dependency was evaluated by the United States National Institute of Standards and Technology and by the German Physikalisch-Technische Bundesanstalt. Center-specific T 1 mapping repeatability (maximum one scan per week to minimum one per quarter year) was assessed over mean 358 (maximum 1161) days on 34 1.5 T and 22 3 T magnets using multiple T 1 mapping sequences. Image and temperature data were analyzed semi-automatically. Repeatability of serial T 1 was evaluated in terms of coefficient of variation (CoV), and linear mixed models were constructed to study the interplay of some of the known sources of T 1 variation. Over 2 years, phantom gel integrity remained intact (no rips/tears), B 0 and B 1 homogenous, and “reference” T 1 stable compared to baseline (% change at 1.5 T, 1.95 ± 1.39%; 3 T, 2.22 ± 1.44%). Per degrees Celsius, 1.5 T, T 1 (MOLLI 5s(3s)3s) increased by 11.4 ms in long native blood tubes and decreased by 1.2 ms in short post-contrast myocardium tubes. Agreement of estimated T 1 times with “reference” T 1 was similar across Siemens and Philips CMR systems at both field strengths (adjusted R 2 ranges for both field strengths, 0.99–1.00). Over 1 year, many 1.5 T and 3 T sequences/magnets were repeatable with mean CoVs < 1 and 2% respectively. Repeatability was narrower for 1.5 T over 3 T. Within T1MES repeatability for native T 1 was narrow for several sequences, for example, at 1.5 T, Siemens MOLLI 5s(3s)3s prototype number 448B (mean CoV = 0.27%) and Philips modified Look-Locker inversion recovery (MOLLI) 3s(3s)5s (CoV 0.54%), and at 3 T, Philips MOLLI 3b(3s)5b (CoV 0.33%) and Siemens shortened MOLLI (ShMOLLI) prototype 780C (CoV 0.69%). After adjusting for temperature and field strength, it was found that the T 1 mapping sequence and scanner software version (both P < 0.001 at 1.5 T and 3 T), and to a lesser extent the scanner model ( P = 0.011, 1.5 T only), had the greatest influence on T 1 across multiple centers. The T1MES CE/FDA approved phantom is a robust quality assurance device. In a multi-center setting, T 1 mapping had performance differences between field strengths, sequences, scanner software versions, and manufacturers. However, several specific combinations of field strength, sequence, and scanner are highly repeatable, and thus, have potential to provide standardized assessment of T 1 times for clinical use, although temperature correction is required for native T 1 tubes at least.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction machine sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.

score de la tête « metaresearch » (Codex)0,016
score de la tête « metaresearch » (Gemma)0,036
Version: metacan-v3-hybrid-931329e0061cStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Expérimental (laboratoire) · Signal consensuel: Expérimental (laboratoire)
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,016
Score d'incertitude au seuil0,082

Scores du classifieur distillé par catégorie (deux têtes)

CatégorieCodexGemma
Métarecherche0,0160,036
Méta-épidémiologie (sens strict)0,0010,000
Méta-épidémiologie (sens large)0,0000,000
Bibliométrie0,0010,001
Études des sciences et des technologies0,0010,001
Communication savante0,0010,001
Science ouverte0,0010,001
Intégrité de la recherche0,0010,000
Charge utile insuffisante (le modèle a refusé de juger)0,0010,001

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,072
Tête enseignante GPT0,284
Écart entre enseignants0,212 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeExpérimental (laboratoire)
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations40
Publié2020
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueJournal of Cardiovascular Magnetic ResonanceMême sujetAdvanced MRI Techniques and ApplicationsTravaux en français237 207