Enhanced Patient Education for Colonic Polyp and Adenoma Detection: Meta-Analysis of Randomized Controlled Trials
Notice bibliographique
Résumé
Background To improve patients’ comprehension of bowel preparation instructions before colonoscopy, enhanced patient education (EPE) such as cartoon pictures or other visual aids, phone calls, mobile apps, multimedia education and social media apps have been proposed. However, it is uncertain whether EPE can increase the detection rate of colonic polyps and adenomas. Objective This meta-analysis aimed to evaluate the efficacy of EPE in detecting colonic polyps and adenomas. Methods We searched PubMed, EMBASE, and Cochrane Central Register of Controlled Trials from their inception to June 2019 for the identification of trials comparing the EPE with standard patient education for outpatients undergoing colonoscopy. We used a random effects model to calculate summary estimates of the polyp detection rate (defined as the number of patients with at least one polyp divided by the total number of patients undergoing selective colonoscopy), adenoma detection rate (defined as the number of patients with at least one adenoma divided by the total number of patients undergoing selective colonoscopy), advanced adenoma detection rate (defined as the number of patients with at least one advanced adenoma divided by the total number of patients undergoing selective colonoscopy), sessile serrated adenoma detection rate (defined as the number of patients with at least one sessile serrated adenoma divided by the total number of patients undergoing selective colonoscopy), cancer detection rate (defined as the number of patients with at least one cancer divided by the total number of patients undergoing selective colonoscopy), or adenoma detection rate - plus (defined as the number of additional adenomas found after the first adenoma per colonoscopy). Moreover, we conducted trial sequential analysis (TSA) to determine the robustness of summary estimates of all primary outcomes. Results We included 10 randomized controlled trials enrolling 4560 participants for analysis. The meta-analysis suggested that EPE was associated with an increased polyp detection rate (9 trials; 3781 participants; risk ratio [RR] 1.19, 95% CI 1.05-1.35; P<.05; I2=42%) and adenoma detection rate (5 trials; 2133 participants; RR 1.37, 95% CI 1.15-1.64; P<.001; I2=0%), which were established by TSA. Pooled result from the inverse-variance model illustrated an increase in the sessile serrated adenoma detection rate (3 trials; 1248 participants; odds ratio 1.76, 95% CI 1.22-2.53; P<.05; I2=0%). One trial suggested an increase in the adenoma detection rate - plus (RR 4.39, 95% CI 2.91-6.61; P<.001). Pooled estimates from 3 (1649 participants) and 2 trials (1375 participants) generated no evidence of statistical difference for the advanced adenoma detection rate and cancer detection rate, respectively. Conclusions The current evidence indicates that EPE should be recommended to instruct bowel preparation in patients undergoing colonoscopy because it can increase the polyp detection rate, adenoma detection rate, and sessile serrated adenoma detection rate. However, further trials are warranted to determine the efficacy of EPE for advanced adenoma detection rate, adenoma detection rate - plus, and cancer detection rate because of limited data.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,004 | 0,002 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,026 | 0,005 |
| Bibliométrie | 0,001 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».