(Invited) Microfluidic Sensors based on Molecularly Imprinted Polymers for the Selective Detection of Volatile Organic Compounds

2020· article· en· W3024274648 sur OpenAlexaff
Mina Hoorfar, Sajjad Janfaza

Notice bibliographique

RevueECS Meeting Abstracts · 2020
Typearticle
Langueen
DomaineChemistry
ThématiqueAnalytical chemistry methods development
Établissements canadiensUniversity of British Columbia
Organismes subventionnairesnon disponible
Mots-clésMolecularly imprinted polymerCoatingAnalyteMicrofluidicsMaterials sciencePolymerAdsorptionMolecular recognitionNanotechnologyMolecular imprintingDesorptionNanoparticleThermal desorptionSelectivityChemical engineeringChemistryMoleculeChromatographyOrganic chemistry

Résumé

récupéré en direct d'OpenAlex

Introduction Selective and sensitive detection of volatile organic compounds (VOCs) is of great importance in applications involving monitoring of hazardous chemicals or non-invasive diagnosis. Diffusion-base microfluidic gas sensors are a new generation of gas detectors. These sensors have increased selectivity; this is primarily due to the effect of diffusion and adsorption/desorption (highly influenced by the coating materials and dimensions of the microfluidic channel) of the analyte molecules along the microfluidic channel (1,2). Therefore, the combination of the diffusion and adsorption/desorption rates of different analytes with different concentrations leads to a unique response (i.e., “smell print”) from the embedded sensor (3). In addition to the coating (or the combination of the layers coated) the surface roughness can affect adsorption and desorption phenomena and hence the performance (mainly selectivity) of the sensors. There are several ways to change the coating and roughness of the channel. One interesting method, which changes the surface material of the microchannel and interaction with the analyte, is the integration of molecularly imprinted polymer nanoparticles (MIP NPs) in to the channel. Column Coating MIP is a synthetic polymer possessing selective molecular recognition properties (due to its binding sites) with size, shape and functionalities complementary to the target molecules. MIPs, often called artificial antibodies or receptors, are alternatives to antibodies in a variety of applications. The advantages of MIPs over natural antibodies include easy and low-cost preparation, longer life cycles (up to several years), highly tailorable recognition properties, solvents and thermal stability, robustness and resistance to a wide range of pH, and ease of regeneration and sterilization. For the first time, MIP NPs were synthesized with acetone recognition sites due to its importance as a biomarker for the non-invasive diagnosis of several diseases like diabetes. The synthesized MIP NPs were integrated into a 3D-printed dual-channel platform (one channel without and the other with MIP NPs) to develop a highly selective detection device against various VOCs (alcohols, ketones, nitrile, and aromatic compounds). Method The MIP NPs with acetone recognition sites were prepared for the first time using the simple precipitation procedure. After polymerization, the solution was centrifuged and the final polymer was ground into a powder. To remove the template, the MIP powder was washed with acetonitrile, followed by heating the powder at 80ºC for 48 h. The morphology and chemical structure of MIP NPs were investigated by field emission scanning electron microscope (FE-SEM, FEI-Nova NanoSEM 450) and Fourier-transform infrared spectroscopy (FTIR, Shimadzu FTIR Prestige 21). The microfluidic-based gas platform consists of two microfluidic channels and gas sensors (embedded at the channel terminus). The microchannels were fabricated from VeroClear RGD810 using a 3D-printer (Connex 500). Each microchannel has equal dimensions of 500 µm in height, 3 mm in width, and 3 cm in length. The inner surfaces of the microchannels are coated with Parylene C using a chemical vapor deposition (CVD) coating machine (SCS PDS 2010 Labcoater). To investigate the effect of treating the channel with MIP NPs on the selectivity of the sensors, one channel was coated with MIP NPs (referred to as the MIP channel) and another one was left uncoated (referred to as the control channel). For this purpose, a certain amount of synthesized MIP NPs dispersed in acetonitrile was drop-casted on the surface of the MIP channel and dried for a day in a clean air chamber. VOCs flow into the channel inlet, diffuse along the microfluidic channel, and reach gas detectors placed at the end of the microchannels, when exposed to the device. The synthesized MIP NPs were integrated into a 3D-printed dual-channel platform (one channel without and the other with MIP NPs) to develop a highly selective detection device against various VOCs (alcohols, ketones, nitrile, and aromatic compounds). A simple feature extraction method was used to distinguish signals arising from different VOCs. The differences between the feature extraction of the two channels showed that in general this platform was specific to acetone, proving the potential application of the MIP NPs in artificial olfaction platforms. Results and Conclusions Fig. 1 shows the response of the dual-channel detector when exposed to 200, 400, 800, 2000, 4000 ppm concentrations of several VOCs. The responses of both detectors increase with increasing concentrations of the target VOC. Although the response of the two detectors to the same target analyte was significantly different, with the increase in the concentration the magnitude of signals increases; however, the time of the maximum response still remains the same. It was also observed that for the low concentration of acetone, butanone and ethanol, the responses from the nano MIP-coated detector are not distinguishable. This again confirms the interaction between these analytes and the MIP NPs. References [1] Paknahad, Mohammad, Carmen Mcintosh, and Mina Hoorfar. "Selective detection of volatile organic compounds in microfluidic gas detectors based on “like dissolves like”." Scientific reports 9.1 (2019): 161. [2] Hoorfar, Mina, Mohammad Paknahad, and Ali Ahmadi. "Apparatus for volatile organic compound (voc) detection." U.S. Patent Application No. 15/800,679. [3] Paknahad, Mohammad, et al. "Characterization of channel coating and dimensions of microfluidic-based gas detectors." Sensors and Actuators B: Chemical 241 (2017): 55-64. Figure 1

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction machine sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.

score de la tête « metaresearch » (Codex)0,000
score de la tête « metaresearch » (Gemma)0,000
Version: metacan-v3-hybrid-931329e0061cStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Expérimental (laboratoire) · Signal consensuel: Expérimental (laboratoire)
GenreSignal candidat: Empirique · Signal consensuel: aucune
Score de désaccord entre enseignants0,007
Score d'incertitude au seuil0,023

Scores du classifieur distillé par catégorie (deux têtes)

CatégorieCodexGemma
Métarecherche0,0000,000
Méta-épidémiologie (sens strict)0,0010,000
Méta-épidémiologie (sens large)0,0000,000
Bibliométrie0,0010,000
Études des sciences et des technologies0,0000,000
Communication savante0,0010,001
Science ouverte0,0010,001
Intégrité de la recherche0,0020,001
Charge utile insuffisante (le modèle a refusé de juger)0,0070,005

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,018
Tête enseignante GPT0,250
Écart entre enseignants0,231 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeExpérimental (laboratoire)
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations0
Publié2020
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueECS Meeting AbstractsMême sujetAnalytical chemistry methods developmentTravaux en français237 207