Arraying of Two Modified Sensors By Controlled Growth of Co-Cu and Functionalized Carbon Nanotube for Highly Sensitive and Selective Non-Enzymatic Sensing of Glucose in Sweat
Notice bibliographique
Résumé
Due to a relation between glucose in sweat and blood, there is an opportunity to monitor the glucose level of patients non-invasively through sweat. There is a high demand for developing highly selective and sensitive biosensors in order to sense biomarkers like glucose and therefore the diseases based on those biomarkers. However enzymatic sensors are selective to specific biomarkers, they are suffering from high sensitivity to the fluctuation of temperature, oxygen, pH, humidity, detergents, organic reagents and toxic chemicals which subsequently affect their stability, sensitivity, and reproducibility. Therefore, developing non-enzymatic sensors have gotten more attention recently due to their stability against those parameters. But these non-enzymatic sensors are almost non-selective toward just one contaminant. Here we proposed a combination of two sensors that can help us to improve the selectivity of these non-enzymatic sensors. Two electrochemical arrayed sensor has been developed. The first electrochemical sensor has been achieved by controlled growth of cobalt nanowire and copper nanoparticles on carbon substrate in order to measure the glucose level at low concentrations and the second electrochemical sensor has been modified by MWCNT- CO-NH-cyanuric-NH2 in order to measure the uric acid and eliminate the interference of it in glucose measurement results. In order to show the morphology of the glucose sensor, the SEM and EDX have been conducted. Also, the FT-IR test has been shown to confirm the functionalization of MWCNT. The electrocatalytic and electrochemical performance of each sensor has been evaluated in the presence of the various contaminants of sweat. The glucose sensor showed the limit of detection (LOD) of 25 μM of glucose and less than 15% interference by ascorbic acid, sodium bicarbonate, lactic acid at the max range of contaminants in the sweat. For eliminating the interference of uric acid, the second sensor has developed which has no response to the glucose and high sensitivity to the uric acid. The calibration curve of each sensor has been provided and a simple method of arraying has been applied to improve the selectivity of the sensors. At the end, the sweat of a male and a female have been collected continuously over 8hours to compare the glucose level of sweat monitored by the sensors and the blood monitored with the commercial glucometer in the same period of time.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,001 |
| Science ouverte | 0,001 | 0,000 |
| Intégrité de la recherche | 0,001 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».