Soon three centres will be treating cancer with beams of negative pions: LAMPF, Los Alamos, U.S.A.; SIN, Villigen, Switzerland; and TRIUMF, Vancouver, Canada. In order to understand this new modality, it will be necessary to compare the results of pion therapy to those achieved with conventional means and to compare results among the three centres. Absolute dosimetry is the basis of this comparison. An absolute dose determination has been made for the negative pion beam at TRIUMF. using an ionization chamber. The relationship required to convert the ionization per unit mass, J/M, measured by the chamber to dose in tissue is D = J/M W r F where W, r and F are calculated quantities. W is the average energy expended in the gas per ion pair produced. Since the W-value for a secondary liberated during pion capture depends upon its energy, it was necessary to average over the energy spectra for the various secondaries. r is the ratio of dose in the wall material, carbon, to dose in the gas, either methane or carbon dioxide. Since the pion secondaries have ranges which are of the same size as the cavity of the ion chamber, it was necessary to explicitly consider those secondaries which emerge from the wall with insufficient energy to cross the cavity and those pions which form stars inside the cavity. Thus, r was found to be pressure dependent. The pressure dependence for carbon dioxide arises as follows:- as the pressure is increased, there are more pion captures in the gas, but since there is less energy released to charged secondaries per pion capture on oxygen than carbon, the dose in the gas decreases. Therefore, the calculation predicted that, as pressure is increased, J/M would remain unchanged for methane, but would decrease rather dramatically for carbon dioxide. F is the ratio of dose in tissue to dose in wall material, carbon in this case. F is the product of two factors: P, which accounts for the difference in the stopping pion density for tissue compared to carbon, and K, which accounts for the difference in energy released per pion capture in tissue compared to carbon. Experimentally, the ionization per unit mass was measured in a parallel plate chamber as a function of pressure for various gases with carbon, aluminum and TE-A150 electrodes. The pressure dependence of J/M measured for methane and carbon dioxide with carbon electrodes was compared to the behavior predicted by the calculation. Qualitatively, the prediction was confirmed: the ionization per unit mass for CO₂ decreases more dramatically with increased pressure than for CH₄. Therefore pion capture in the gas is significant and the energy released to charged secondaries per pion capture on oxygen is less than for carbon. Quantitatively, the percentage change is larger than predicted. The value of J/M extrapolated to zero pressure and the appropriate values calculated for W and r enabled a determination of the absolute dose in carbon with an estimated accuracy of ± 5%. The ionization created with aluminum electrodes was compared to that for carbon in order to estimate the dose in aluminum. After considering the dose contribution from beam contaminants, the value of F required to convert dose in carbon to dose in tissue was estimated to be 0.93 ± 0.05. Therefore, the absolute dose in tissue was determined to an accuracy of ± 7%. In order to increase the accuracy, it is necessary to improve the data available as input to the calculation.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».