Dosimetric evaluation of whole-pelvis radiation therapy of prostate cancers: clinical experience
Notice bibliographique
Résumé
Abstract Background: The standard treatment modalities for prostate cancer include surgery, chemotherapy, hormonal therapy and radiation therapy or any combination depending on the stage of the tumour. Radiation therapy is a common and effective treatment modality for low-intermediate-risk patients with localised prostate cancer, to treat the intact prostate and seminal vesicles or prostate bed post prostatectomy. However, for high-risk patients with lymph node involvement, treatment with radiation will usually include treatment of the whole pelvis to cover the prostate and seminal vesicles or prostate bed and the pelvic lymph nodes followed by a boost delivery dose to the prostate and seminal vesicles or prostate bed. Materials and Methods: We retrospectively analysed the treatment plans for 179 prostate cancer patients treated at the cancer centre with the volumetric-modulated arc therapy (VMAT) technique via RapidArc using 6 MV photon beam. Patients were either treated with a total prescription dose of 78 Gy in 39 fractions for patients with intact prostate or 66 Gy in 33 fractions for post prostatectomy patients. Results: There were 114 (64%) patients treated with 78 Gy/39 and 65 (36%) treated with 66 Gy/34. The mean homogeneity index (HI), conformity index (CI) and uniformity index (UI) for the PTV-primary of patients treated with 78 Gy are 0.06 ± 0.01, 1.04 ± 0.01 and 0.99 ± 0.01, respectively, and the corresponding mean values for patients treated with 66 Gy are 0.06 ± 0.02, 1.05 ± 0.01 and 0.99 ± 0.01, respectively. The mean PTV-primary V 95% , V 100% and V 105% are 99.5 ± 0.5%, 78.8 ± 12.2% and 0.1 ± 0.5%, respectively, for patients treated with 78 Gy and 99.3 ± 0.9%, 78.1 ± 10.6% and 0.1 ± 0.4%, respectively, for patients treated with 66 Gy. The rectal V 50Gy , V 65Gy , V 66.6Gy , V 70Gy , V 75Gy and V 80Gy are 26.8 ± 9.1%, 14.2 ± 5.3%, 13.1 ± 5.0%, 10.8 ± 4.3%, 6.9 ± 3.1% and 0.1 ± 0.1%, respectively, for patients treated with 78 Gy and 33.7 ± 8.4%, 14.1 ± 4.5%, 6.7 ± 4.5%, 0.0 ± 0.2%, 0.0% and 0.0%, respectively, for patients treated with 66 Gy. Conclusion: The use of VMAT technique for radiation therapy of high-risk prostate cancer patients is an efficient and reliable method for achieving superior dose conformity, uniformity and homogeneity to the PTV and minimal doses to the organs at risk. Results from this study provide the basis for the development and implementation of consistent treatment criteria in radiotherapy programs, have the potential to establish an evaluation process to define a consistent, standardised and transparent treatment path for all patients that reduces significant variations in the acceptability of treatment plans and potentially improve patient standard of care.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,002 | 0,002 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,001 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».