School leadership certification programmes : London, New York and Toronto
Notice bibliographique
Résumé
First time we launch an innovative and simple portable in a closed micropipette tip switchable hydrophilicity microextraction syringe system (µS-SHS) couple with electrothermal atomic absorption spectroscopy (ETAAS) was developed for preconcentration and determination of vanadium using 2-(5-Bromo-2-pyridylazo)-5-diethylaminophenol (5- Br-PADAP), as complexing. In the proposed method decanoic acid was used as a switchable hydrophilicity extraction solvent and their polarity was switched on and off (water miscible/immiscible) by simply changing their pH. The phase separation was induced by simply adding sulfuric acid that switch off hydrophilicity (nondispersed/immiscible) of decanoic acid. The metal complex enriched phase (V-(5-Br-PADAP-SHS) was separated by simply removing the aqueous phase through manually dispensed syringe system. Then finally acidic ethanol drawn into the syringe contains metal complex enriched SHS phase to reduce viscosity and directly injected into the ETAAS by using an enclosed micropipette tip syringe system. The multivariate strategy was applied to screen out and optimized the variables. Limit of detection (LOD), enhancement factor (EF) and relative standard deviation (RSD) were found 0.0075 µg L<sup>-1</sup>, 120 and 2.91%, respectively. Certified reference material of riverine water (SLRS-4), Apple leaves (NIST SRM 1515) and a standard addition method was used to validate the present method. Developed method was applied to water and food samples. We successfully applied the proposed method to analyze vanadium in different real food and water samples.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,001 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,001 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,004 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».