MétaCan
Menu
Retour à la cohorte
Enregistrement W3088774320 · doi:10.1097/opx.0000000000001580

Advances in Scleral Lenses

2020· article· en· W3088774320 sur OpenAlexaboutno aff
Andrew D. Pucker

Notice bibliographique

RevueOptometry and Vision Science · 2020
Typearticle
Langueen
DomaineMedicine
ThématiqueOphthalmology and Visual Impairment Studies
Établissements canadiensnon disponible
Organismes subventionnairesnon disponible
Mots-clésScleral lensOptometryOphthalmologyMedicineCornea

Résumé

récupéré en direct d'OpenAlex

The specialty lens landscape has dramatically changed in my short career as an optometrist (Fig. 1).1 When I graduated from an optometry school in 2011, corneal gas-permeable lenses were the long-standing modality of choice for correcting complicated refractive errors, and most practitioners were reserving scleral lenses for only their most challenging cases. However, now with many more manufacturers producing scleral lenses and with the advent of safe, highly customizable scleral lenses, this modality is quickly becoming a treatment of choice for patients with irregular astigmatism and advanced refractive errors and for patients who need a long-term bandage lens for chronic dry eye–related conditions; some practitioners are now even prescribing scleral lenses for uncomplicated refractive errors, including presbyopia.1FIGURE 1: Andrew D. Pucker, OD, PhD, FAAO.This newfound interest in scleral lens technology has resulted in the creation of the Scleral Lens Education Society (https://sclerallens.org/), which is an international society focused on teaching “contact lens practitioners the science and art of prescribing scleral contact lenses.” This organization invites and educates everyone interested in scleral lenses. The Scleral Lens Education Society also has a fellowship program for practitioners who have demonstrated advanced knowledge of scleral lenses. The Scleral Lens Education Society provides resources and scleral lens–related updates to keep the community fully aware of the latest and greatest advances in the field. These exciting developments have all contributed to the creation of this feature issue, which highlights the cutting-edge research that is being conducted. Furthermore, this feature issue showcases the diversity and international interest in scleral lenses, with articles originating from Australia, Canada, China, Germany, India, Iran, Italy, the Netherlands, Nigeria, Portugal, Spain, the United Kingdom, the United States, and 29 different institutions. Of note, this issue also highlights the work of many women who are innovatively leading advancements in the scleral lens field. A number of themes emerged as articles were reviewed for this special issue. One prominent theme, which has been a challenge with scleral lenses since their introduction, is ocular compatibility.2 Some of the ocular compatibility issues discussed in this feature issue include tear film interactions with lenses,3,4 physical and optical interaction between the eye and the lens,5–10 and oxygen availability.11–16 Oxygen availability has been an issue with scleral lenses since their inception because the first lenses were made of glass, which is impermeable to oxygen, and because of this, scleral lenses were worn for only short periods.2 The advent of gas-permeable scleral lenses in 1983 dramatically alleviated this issue,17 although many investigators still question whether scleral lenses allow for sufficient oxygen to meet the metabolic demands of the cornea.18,19 Corneal oxygenation may still be an issue with scleral lenses because the tears trapped between the lens and eye are a greater barrier to oxygen than the lens itself.18–20 Dhallu et al.11 in this issue demonstrated that all scleral lenses, in normal participants, regardless of their oxygen permeability, induce some mild stromal corneal swelling, although oxygen consumption was optimized when the tested lenses had a Dk of ≥125. Tse et al.12 furthermore found no changes in corneal epithelial barrier function, nerve fiber, or dendritic cell densities in normal participants who wore scleral lenses for 3 months. Nevertheless, in normal participants, Fisher et al.13 found that corneal edema increases with increasing central tear reservoir thicknesses, although this increase in edema was only 2.12% when lenses had central tear reservoir thicknesses between 600 and 800 μm. Another theme related to the tear reservoir is midday fogging.20 This bothersome issue, unique to scleral lens wear, results in blurry vision from a particulate matter that has yet to be fully characterized, although there is some evidence that fogging results from a buildup of tear lipids, tear proteins, or inflammatory cells.20,21 Fogt et al.3 investigated if this fogging could be mitigated by a novel saline solution that mimics human tears. Although the authors found that the novel saline solution improved ocular symptoms, they did not find a significant difference in fogging when comparing this optimized saline solution with the participants' habitual solution. This exciting result provides evidence suggesting that we should be testing new saline formulation that better mimics the tears, so we can further increase scleral lens ocular compatibility and decrease scleral lens issues such as midday fogging. Although the aforementioned articles suggest that scleral lenses are safe in normal patients, safety may still be an issue in patients who have compromised corneas because these corneas may have less of an ability to deal with decreased oxygenation.16 Kumar et al.16 report in this issue that participants who have undergone penetrating keratoplasty have greater scleral lens–induced corneal edema than do normal participants, although the amount of edema detected in this study is likely to be within an acceptable amount based on the Holden-Mertz criteria.22 The use of scleral lenses in participants who have undergone penetrating keratoplasty is also supported in this issue by a case study by Gulmiri and Jawanda,15 which found that scleral lenses have the potential to stave off the need for corneal regrafting. Yeung et al.14 alternatively evaluated the effect of limbal clearance rather than central clearance on ocular signs and symptoms in patients with keratoconus and found that when participants were fit in lenses with higher (~167 μm) limbal clearances, they found the lenses to be more comfortable than lower (~124 μm) limbal clearances, although there were no differences in limbal or bulbar hyperemia. The result from the study by Yeung et al. in a patient with keratoconus suggests that limbal clearance studies in other populations should be conducted to determine if higher limbal clearances likewise improve comfort in these patient groups. Because scleral lenses rest on the sclera/episclera, they may increase intraocular pressure (IOP) by altering aqueous humor dynamics. This is a particularly important issue because some scleral lens wearers have glaucoma, which could be exacerbated by IOP spikes induced by scleral lens wear. Management of glaucoma in patients wearing scleral lens is complicated by the fact that IOP cannot be easily monitored via conventional methods during lens wear. Therefore, pressure measurements need to either be conducted either before and after scleral lens wear or via a scleral measurement rather than a corneal measurement. In this issue, Fogt et al.23 compared IOP measurements in normal eyes taken by two different devices (pneumatonometry and transpalpebral tonometry) and found that the two instruments yielded significantly different measurements, which indicates that IOP measurements are not straightforward and that using different instruments may result in different study conclusions. Walker et al.24 alternatively found no difference in IOP in normal eyes when evaluating IOP with the iCare (iCare USA, Raleigh, NC) and Diaton devices (Diaton, DevelopAll Inc.). The authors also found little effect on IOP or optic nerve head morphology when comparing lens wearing eyes with non–lens-wearing eyes after 6 hours of lens wear.24 Obinwanne et al.25 similarly found no clinically meaningful changes in IOP before, during, or after scleral lens wear with the Schiotz tonometer in a normal African population. Therefore, although scleral lens wear seems to have a small impact on IOP that is device dependent, the current literature suggests that scleral lens wear is unlikely to make glaucoma worse. Nevertheless, more work is needed to fully understand how scleral lenses may alter the eye's ability to regulate IOP and subsequently lead to glaucomatous optic nerve changes. Because scleral lenses rest on tissue containing goblet cells, constant mechanical interaction between the ocular surface and lenses may potentially negatively impact these important cells. Scleral lens–induced alterations in mucin production may promote long-term tissue changes that could destabilize the tear film and lead to contact lens–induced dry eye disease.26 Fortunately, Macedo-de-Araújo et al.4 found in this issue no regional (inferior vs. superior bulbar conjunctiva) differences in goblet cell densities or mucin cloud amplitudes in lens wearers, which provides evidence that scleral lenses are unlikely to make dry eye worse through goblet cell damage. This is an important finding because scleral lenses are a key means for treating recalcitrant dry eye.27–29 Prospective, longitudinal studies are still needed to fully understand the benefits of scleral lenses for dry eye disease. Corneal irregularity is a primary indication for scleral lens wear1; however, even with standard scleral lenses, higher-order aberrations may decrease the quality of vision in patients with corneal irregularity. Incorporation of correction for these aberrations onto various contact lens platforms has been considered for many years, but the translational and rotational stability of scleral lenses may finally allow this technology to come to fruition. Correction of higher-order aberrations has the potential to improve the acuity and visual perception of patients who may be unhappy with the quality of their vision even if they have normal Snellen acuity. Several studies included in this issue report on scleral lens technology that is able to mitigate higher-order aberrations. Rijal et al.5 demonstrate in this issue that customizing the lens location of the optical design for each participant is better than adopting a fixed lens location for scleral lenses that have wavefront-guided optics. Assadpour et al.6 found that scleral lenses were able to reduce higher-order aberrations to a similar extent to that of hybrid lenses in participants with keratoconus. The case report by Nguyen et al.7 demonstrates the clinical applicability of this concept; quality of vision in a patient with bilateral keratoconus improved with wavefront-guided scleral lenses, even though he was already able to achieve 20/20 visual acuity with his habitual correction. The final study related to optical performance of scleral lenses by Wilting et al.8 shows that a year's worth of lens cleaning does not have a clinically meaningful impact on optical aberrations or scleral lens shape. Obtaining an optimal lens fit may also maximize lens performance, which is one of the likely next big areas of scleral lens research. Studies on fit optimization should investigate how lens fit influences ocular health, contact lens optics, and lens designs and how they all interact with each other to provide the optimal scleral lens–wearing experience. Barnett et al.10 provide a retrospective study that found that quadrant-specific scleral lenses resulted in better visual acuity and a reduced need for midday contact lens removal compared with their habitual correction. Fadel and Ezekiel30 also provided a review in this issue that describes the history, indications, and fitting strategies of fenestrated scleral lenses. Early studies of scleral contour have used full-field ocular surface topography for lens fitting. In this issue, Banditz et al.9 found that Fourier-based profilometry and Scheimpflug imaging yield different sagittal height and toricity measurements; this suggests that these two technologies are not interchangeable. Imaging devices such as these are now commonly being used to help design quadrant-specific or freeform scleral lenses. This issue provides additional evidence related to the efficacy of scleral lenses. In a 12-month study, Macedo-de-Araújo et al.31 found that visual acuity with scleral lenses was better than that which was provided by previous habitual correction in participants who had either regular or irregular corneas, although they found that participants with irregular corneas experienced greater improvements. Shorter et al.32 also found that scleral lens wearers with keratoconus demonstrated greater visual and comfort satisfaction compared with participants who wear corneal gas-permeable lenses. These data provide additional justification for considering scleral lenses as the first treatment of choice for complicated refractive errors. Nevertheless, the community is still lacking large-scale, longitudinal studies related to scleral lens safety. This lack of information is currently being addressed by a new, international study group called the Consortium for Research in Scleral Lenses, which is open to all practitioners who are interested in scleral lens research. Thus, exciting research on this timely topic is forthcoming. Another hot topic within the vision science community is controlling myopic progression.33 This issue features an article by Peguda et al.,34 who used scleral lenses, which generally have little movement while on the eye, to model the optical effects of two different optic zones for orthokeratology-based myopia management. The authors provide data indicating that a 4-mm optic zone may provide more desirable myopia control optics than a 6-mm optic zone. Although scleral lenses themselves have not been routinely used as a myopia management strategy, work by Peguda et al.34 suggests that scleral lenses have the optical potential to slow the progression of myopia, especially in progressing myopes who are unable to wear other more commonly used contact lenses because of advanced refractive errors, ocular surface disease, or discomfort that is associated with other more commonly used contact lens modalities. The amount of enthusiasm and interest in this feature issue was exciting and highlighted by the many outstanding articles we received. The creation of this issue could not have been possible without the help of the guest editors and the many reviewers who volunteered their time to bring the most current, high-quality scleral lens–related research together. I sincerely hope that you enjoy this issue. I am sure that it will help shape your practice and scientific pursuits. Andrew D. Pucker, OD, PhD, FAAO

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,000
score de la tête « metaresearch » (Gemma)0,000
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Observationnel · Signal consensuel: Observationnel
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,025
Score d'incertitude au seuil0,179

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0000,000
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0000,000
Bibliométrie0,0000,001
Études des sciences et des technologies0,0000,000
Communication savante0,0000,000
Science ouverte0,0000,000
Intégrité de la recherche0,0000,000
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,042
Tête enseignante GPT0,499
Écart entre enseignants0,458 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeObservationnel
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations0
Publié2020
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueOptometry and Vision ScienceMême sujetOphthalmology and Visual Impairment StudiesTravaux en français237 207