BACKGROUND: The integration of high technology into health care systems is intended to provide new treatment options and improve the quality, safety, and efficiency of care. Robotic-assisted surgery is an example of high technology integration in health care, which has become ubiquitous in many surgical disciplines. OBJECTIVE: This study aims to understand and measure current robotic-assisted surgery processes in a systematic, quantitative, and replicable manner to identify latent systemic threats and opportunities for improvement based on our observations and to implement and evaluate interventions. This 5-year study will follow a human factors engineering approach to improve the safety and efficiency of robotic-assisted surgery across 4 US hospitals. METHODS: The study uses a stepped wedge crossover design with 3 interventions, introduced in different sequences at each of the hospitals over four 8-month phases. Robotic-assisted surgery procedures will be observed in the following specialties: urogynecology, gynecology, urology, bariatrics, general, and colorectal. We will use the data collected from observations, surveys, and interviews to inform interventions focused on teamwork, task design, and workplace design. We intend to evaluate attitudes toward each intervention, safety culture, subjective workload for each case, effectiveness of each intervention (including through direct observation of a sample of surgeries in each observational phase), operating room duration, length of stay, and patient safety incident reports. Analytic methods will include statistical data analysis, point process analysis, and thematic content analysis. RESULTS: The study was funded in September 2018 and approved by the institutional review board of each institution in May and June of 2019 (CSMC and MDRH: Pro00056245; VCMC: STUDY 270; MUSC: Pro00088741). After refining the 3 interventions in phase 1, data collection for phase 2 (baseline data) began in November 2019 and was scheduled to continue through June 2020. However, data collection was suspended in March 2020 due to the COVID-19 pandemic. We collected a total of 65 observations across the 4 sites before the pandemic. Data collection for phase 2 was resumed in October 2020 at 2 of the 4 sites. CONCLUSIONS: This will be the largest direct observational study of surgery ever conducted with data collected on 680 robotic surgery procedures at 4 different institutions. The proposed interventions will be evaluated using individual-level (workload and attitude), process-level (perioperative duration and flow disruption), and organizational-level (safety culture and complications) measures. An implementation science framework is also used to investigate the causes of success or failure of each intervention at each site and understand the potential spread of the interventions. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): DERR1-10.2196/25284.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,085 | 0,073 |
| Méta-épidémiologie (sens strict) | 0,005 | 0,003 |
| Méta-épidémiologie (sens large) | 0,005 | 0,005 |
| Bibliométrie | 0,005 | 0,005 |
| Études des sciences et des technologies | 0,005 | 0,004 |
| Communication savante | 0,004 | 0,003 |
| Science ouverte | 0,004 | 0,003 |
| Intégrité de la recherche | 0,006 | 0,007 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,034 | 0,008 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».