Numerical Assessment of an Air Cleaner Device under Different Working Conditions in an Indoor Environment
Notice bibliographique
Résumé
Transmission and spread of exhaled contaminants in the air may cause many airborne infectious diseases. In addition to appropriate ventilation, air cleaner devices are used as one of the most common ways to improve the indoor air quality. Therefore, it is necessary to understand the performance of an air cleaner under different operating conditions. This study mainly concerns investigating the effect of presence or absence of furniture and its displacement on the removal rate of the particles leaving a person’s mouth while coughing in an isolated room. Moreover, the effect of air exit angle of the device on removal rate of contaminated particles and the pattern of their dispersion within a room was studied. To this aim, computational fluid dynamics were employed to examine the mentioned effects by using the Eulerian− Lagrangian method. As the results indicated, when the furniture was placed farther away from the device, more particles were removed by the device. Additionally, the air ejection angle of the air cleaner device significantly affects the removal of particles. Results of the present study could improve use of air cleaner devices for maximum reduction of particles in the indoor environment.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».