Review of Biomedical Applications of Contactless Imaging of Neonates using Infrared Thermography and Beyond
Notice bibliographique
Résumé
The monitoring of sick newborns is a challenging task that health care providers in Neonatal Intensive Care Units (NICU) must contend with each day. Conventionally, newborns are monitored via probes that are affixed to their skin and attached to processing monitors (Fig.1). However, an alternative exists in contactless imaging to record such physiological signals (Physio-Markers), surface changes and internal structures which can be used independently of, or in conjunction with conventional monitors. Advantages of contactless monitoring methods include: i) quick data generation; ii) lack of contact with skin, which reduces skin breakdown and decreases risk of infection; and iii) minimizing the number of probes and monitors affixed to the skin, which allows greater body surface-area for other care. This paper is an attempt to build a foundation for and to provide a vision of the potential neonatal clinical applications of technologies that use non-contact modalities such as Visible Light Imaging (VLI), Near InfraRed Spectrum (NIRS), and Thermal Imaging (TI) using InfraRed Spectrum (IRS).
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,002 | 0,000 |
| Bibliométrie | 0,001 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,002 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,001 |
| Intégrité de la recherche | 0,000 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».