Third-Party Damage Monitoring: Internal Fiber Optic Installation on a Transmission Pipeline Using a Pig, a Disengagement System and a Pack-Off Hanger
Notice bibliographique
Résumé
Abstract The risk associated with third-party damage to transmission pipelines in areas of urban development is high. Distributed monitoring is a modern technique that uses fiber optic cables as sensors to continuously monitor pipeline parameters such as acoustics, vibration, strain and temperature. The fiber optic system notifies the operator in real-time of ongoing events allowing decisions to be made to prevent external interference or quickly address an incident that has already occurred. Traditional methods used to install distributed monitoring systems on pipelines have limitations and are not feasible for all transmission pipelines. For instance, it can be both challenging and expensive to trench in fiber optics in developed areas and other installation techniques require the pipeline to be temporarily taken out of service. SaskEnergy Incorporated’s transmission line subsidiary, TransGas Limited partnered with a Canadian pipeline monitoring service provider to install fiber optics inside of a natural gas transmission pipeline using a pig, steel capillary tubing and a pack-off hanger. A disengagement system was incorporated to release the fiber optics after the desired monitoring distance was reached. It was decided to perform the pilot project on a newly constructed NPS 6 natural gas transmission pipeline located in Humboldt, Saskatchewan. Nitrogen was used as a medium to simulate an in-service pipeline in order to reduce the risks associated with the first attempt of the project designs. The fiber optics were inserted into steel capillary tubing and connected to a disengagement system located at the back of a pig. A pack-off hanger was used to maintain pipeline pressure during and after the installation was completed. The spool holding the steel capillary tubing was stopped once the maximum monitoring distance was reached and the differential pressure activated the disengagement system located at the back of the pig. The pig continued to the receive location and the fiber optics remained in the pipeline for continuous monitoring. The deployment was successful and the fiber optics will remain in the pipeline for a one (1) year monitoring period. The primary limitation to this pilot project was the strength of the steel capillary tubing. The steel capillary tubing’s ultimate tensile strength would have to be higher to accommodate a pipeline with a larger outside diameter, multiple bends, large changes in wall thickness or large elevation changes. In addition, the steel capillary tubing must be removed from the pipeline in order to perform pigging activities.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,001 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,001 | 0,001 |
| Communication savante | 0,000 | 0,001 |
| Science ouverte | 0,001 | 0,001 |
| Intégrité de la recherche | 0,001 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,002 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».