MétaCan
Menu
Retour à la cohorte
Enregistrement W3128013324 · doi:10.1093/ehjci/jeaa356.259

Application of a machine learning contouring tool for the evaluation of left ventricular strain in clinical practice

2021· article· en· W3128013324 sur OpenAlexaffabout
Asmaa A M Kenawy, M Y Khanji, M Chirvasa, Kenneth Fung, Alireza Sojoudi, José Miguel Paiva, N Samy, Wala Abdelaziz Farid, TS Khalil, Steffen E. Petersen

Notice bibliographique

RevueEuropean Heart Journal - Cardiovascular Imaging · 2021
Typearticle
Langueen
DomaineMedicine
ThématiqueCardiac Imaging and Diagnostics
Établissements canadiensCircle Cardiovascular Imaging
Organismes subventionnairesEuropean Regional Development FundEngineering and Physical Sciences Research CouncilBarts Health NHS TrustBarts CharityUK Research and Innovation
Mots-clésGeneral partnershipChristian ministryGovernment (linguistics)ChampionMedicineHealth careManagementPolitical scienceMedical educationBusinessFinanceEconomics

Résumé

récupéré en direct d'OpenAlex

Abstract Funding Acknowledgements Type of funding sources: Private grant(s) and/or Sponsorship. Main funding source(s): AK has been funded by the Egyptian cultural centre and educational bureau of the Egyptian embassy in London and the Ministry of higher education in Egypt. SEP acknowledges support from the “SmartHeart” EPSRC programme grant (www.nihr.ac.uk; EP/P001009/1) and the London Medical Imaging and AI Centre for Value-Based Healthcare. This new centre is one of the UK Centres supported by a £50m investment from the Data to Early Diagnosis and Precision Medicine strand of the government’s Industrial Strategy Challenge Fund, managed and delivered by UK Research and Innovation (UKRI). SEP acknowledges support from the CAP-AI programme, London’s first AI enabling programme focused on stimulating growth in the capital’s AI Sector. CAP-AI is led by Capital Enterprise in partnership with Barts Health NHS Trust and Digital Catapult and is funded by the European Regional Development Fund and Barts Charity. SEP also acts as a paid consultant to Circle Cardiovascular Imaging Inc., Calgary, Canada and Servier onbehalf Barts Heart Centre, St Bartholomew’s Hospital, Barts Health NHS Trust, West Smithfield, London, UK Background Manual contouring of cardiovascular magnetic resonance (CMR) cine images remains common practice and the reference standard for left ventricular (LV) volumes and mass evaluation. However, it is time-consuming and machine learning (ML) may significantly reduce the time required for contouring. Accurate LV contours are the basis for reliable LV strain analysis using tissue tracking. Purpose To assess the impact of a ML contouring tool alone versus expert adjusted contours on LV strain. Methods We retrospectively selected 402 CMR studies with diagnoses of myocardial infarction (n = 108), myocarditis (n = 130) and healthy controls (n = 164) from the Barts BioResource between January 2015 to June 2018. CMR examinations were obtained using 1.5T and 3T scanners (Siemens Healthineers, Germany). We excluded 32 cases due to phase inconsistency between short (SAX) and long axes (LAX) cine images or suboptimal cine image quality. For the remaining 370 cases, steady state free precession cine images for LAX and SAX were analysed by the ML contouring tool (using CVI42 research prototype software 5.11). Manual expert adjustment for the contours was done for each case if considered suboptimal for strain analysis in the reference end-diastolic phase. Strain results from ML and expert adjusted ML methods were compared for strain agreement. Times taken by these methods were recorded and compared against the time taken for standard manual contouring. Results SAX and LAX derived strains by ML and expert adjusted ML methods showed good agreement by Bland-Altman analysis (Figure 1) with excellent coefficient of concordance using Kendall W which is 0.98 for global SAX, radial and circumferential strains (mean difference(MD) = -1.7% (lower and upper limits of agreement (UL,LL) -6.6,3.2), MD = 0.5% (-1.0,2.1)) and is 0.95 for global LAX derived strain (radial and longitudinal, MD = 0.7% (UL,LL -8.7 ,7.4),MD= 0.2% (-1.9,2.5), respectively). Time taken for adjustment of ML contours was significantly shorter than manual contouring (1.35 minutes vs 8.0 minutes, around 590% time saving in ML adjusted method). Conclusions ML contouring compared to expert manual adjustment has a clinically reasonable agreement when used for measuring LV strain. Also, using the ML tool with expert adjustment shows significant time saving for analysis and reporting time compared to entirely manual analysis, favouring its application in routine clinical practice. Abstract Figure.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,023
score de la tête « metaresearch » (Gemma)0,018
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesMétarecherche
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Observationnel · Signal consensuel: aucune
GenreSignal candidat: Empirique · Signal consensuel: aucune
Score de désaccord entre enseignants0,716
Score d'incertitude au seuil0,991

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0230,018
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0010,001
Bibliométrie0,0000,000
Études des sciences et des technologies0,0000,000
Communication savante0,0000,000
Science ouverte0,0000,000
Intégrité de la recherche0,0000,001
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,047
Tête enseignante GPT0,369
Écart entre enseignants0,322 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.

Devis d'étudeObservationnel
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations0
Publié2021
Routes d'admission2
Résumé présentoui

Explorer davantage

Même revueEuropean Heart Journal - Cardiovascular ImagingMême sujetCardiac Imaging and DiagnosticsTravaux en français237 207