Kinematic alignment of medial UKA is safe: a systematic review
Notice bibliographique
Résumé
PURPOSE: Owing to the improved understanding of knee kinematics and the successful introduction of the kinematic alignment (KA) technique for implanting total knee arthroplasty (TKA), it was recently understood that the "Cartier angle technique" corresponds to a kinematic implantation of the uni-compartmental knee arthroplasty (UKA) components. When compared to the universally spread mechanical alignment (MA) technique for implanting UKA, the KA method generates a more anatomic prosthetic knee that may be clinically advantageous. The aims of this study are to determine if KA UKAs are associated with acceptable functional performance and patient satisfaction (question 1), rates of residual pain and tibia plateau fracture (question 2), and rates of reoperation and revision (question 3), and to define the component orientation and limb alignment as measured on radiograph (question 4), and the stress shielding related bone loss in the proximal tibia (question 5) with KA UKA, and where possible to compare with MA UKA. STUDY HYPOTHESIS: KA UKA generates good clinical outcomes, similar or superior to the ones of MA UKA. METHOD: Systematic review of literature databases were primarily searched using Healthcare Databases Advanced Search (HDAS). Two primary searches were conducted using the electronic databases MEDLINE, EMBASE, and PubMed, and a secondary search was conducted using review articles and bibliography of obtained papers in order to ascertain more material. RESULTS: Nine eligible non-comparative prospective (3) or retrospective (6) cohort studies, which cumulated 593 KA UKAs with follow-up between 3.2 and 12 years, fulfilled the inclusion criteria for this systematic review. The findings demonstrated high Knee Society Score (KSS) (from 87 to 95) and function scores (from 81 to above 91) in addition to patient satisfaction scores of 88%. There was no revision for tibia plateau fracture, 0.8% (5 cases) for unexplained pain tibia, 2.0% (12 cases) for component loosening, and 5.6% (33 cases) for any causes of aseptic failures reported for KA UKA. The prosthetic lower limb and tibia implant alignments were both found to be in slight varus (means between 3 and 5°), and the postoperative joint line and tibia component was shown to be parallel to the floor when standing. The KA UKA components migration, as measured on radiostereometry, was acceptable. DISCUSSION/CONCLUSION: The KA technique is an alternative, personalised, more physiological method for implanting UKA, which could be clinically advantageous when compared to the MA technique. The literature supports the good mid- to long-term clinical safety and good efficacy of KA UKA; however, comparison between KA and MA techniques for UKA was not performed due to limited literature. Further investigations are needed to better define the clinical impact of KA UKA, and the acceptable limits for KA of the UKA tibial component. LEVEL OF EVIDENCE: Level 4; systematic review of level 4 studies.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,008 | 0,042 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,001 |
| Méta-épidémiologie (sens large) | 0,008 | 0,007 |
| Bibliométrie | 0,009 | 0,011 |
| Études des sciences et des technologies | 0,001 | 0,001 |
| Communication savante | 0,003 | 0,003 |
| Science ouverte | 0,002 | 0,001 |
| Intégrité de la recherche | 0,002 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,005 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».