A failure analysis was performed on an Alloy C-276 pull rod which underwent unexpected brittle, intergranular fracture after exposure to 280°C to 300°C aqueous solutions designed to replicate secondary side environments in nuclear energy systems: Pb-containing alkaline (pH300°C 8.5 to 9.5), and sulfate-containing acidic solutions (pH280°C 3 to 5). The component was characterized using advanced electron microscopy methods to demonstrate the benefits of these techniques for determining the nanoscale chemical, mechanical, and material factors contributing to failure, and to provide insight into the mechanisms of stress corrosion cracking (SCC) responsible for failure. Site-specific transmission electron microscopy specimens containing crack tips were prepared using focused ion beam. Nanoscale chemical characterization methods revealed that Pb was present in some oxidized regions of cracks, suggesting that the element may be inhibiting or impairing the passivity of the Cr-rich oxide. Complementary nanoscale microstructural analysis was performed. At an intergranular to transgranular cracking mode transition, it was observed that the transgranular crack (and corrosion process) propagated along the (110) crystallographic plane. Also, the cracking mode was highly dependent on the tensile stress direction relative to grain boundary orientation, the crystallographic orientation of grains, and geometrically necessary dislocation structures. A comparison of results with proposed mechanisms for SCC of Ni alloys in similar environments are discussed; the highly directional nature of cracking is consistent with a slot-tunnel corrosion mechanism.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,002 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».