Heat transfer augmentation in a circular tube fitted with tri-partition flow splitters
Notice bibliographique
Résumé
This paper focuses on the numerical and experimental study of a heated tubes heat transfer and flow characteristics with a novel tri-partition flow splitter under forced convection. A low thermal conducting fluid like air is considered to be a working fluid. Tri-partition flow splitters were manufactured with different thickness and arranged alternatively with 180° rotations to change the direction of airflow. Seven Reynolds number in the range of 5000–15,000 were considered as an operating parameter. The results of the plain tube are validated with the standard Dittus–Boelter and Gnielinski equations available in literature. In addition, the experimental results with tri-partition flow splitters are used to validate the computational fluid dynamics model used to examine the flow characteristics in the heated tube. The overall thermal performance enhancement is evaluated by the performance evaluation criteria (PEC). The results showed that the Nusselt number (Nu) is increased with an increase in Reynolds number. The maximum PEC 1.98 is obtained for 2 mm thickness splitters. The highest Nusselt number (Nu = 271.99) is found for 10 mm thickness with a higher friction drop. Friction factor values are found dropped by reducing the thickness of the splitters.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».