Adherence to Lung-Protective Ventilation Principles in Pediatric Acute Respiratory Distress Syndrome: A Pediatric Acute Respiratory Distress Syndrome Incidence and Epidemiology Study*
Notice bibliographique
Résumé
OBJECTIVES: To describe mechanical ventilation management and factors associated with nonadherence to lung-protective ventilation principles in pediatric acute respiratory distress syndrome. DESIGN: A planned ancillary study to a prospective international observational study. Mechanical ventilation management (every 6 hr measurements) during pediatric acute respiratory distress syndrome days 0-3 was described and compared with Pediatric Acute Lung Injury Consensus Conference tidal volume recommendations (< 7 mL/kg in children with impaired respiratory system compliance, < 9 mL/kg in all other children) and the Acute Respiratory Distress Syndrome Network lower positive end-expiratory pressure/higher Fio2 grid recommendations. SETTING: Seventy-one international PICUs. PATIENTS: Children with pediatric acute respiratory distress syndrome. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Analyses included 422 children. On pediatric acute respiratory distress syndrome day 0, median tidal volume was 7.6 mL/kg (interquartile range, 6.3-8.9 mL/kg) and did not differ by pediatric acute respiratory distress syndrome severity. Plateau pressure was not recorded in 97% of measurements. Using delta pressure (peak inspiratory pressure - positive end-expiratory pressure), median tidal volume increased over quartiles of median delta pressure (p = 0.007). Median delta pressure was greater than or equal to 18 cm H2O for all pediatric acute respiratory distress syndrome severity levels. In severe pediatric acute respiratory distress syndrome, tidal volume was greater than or equal to 7 mL/kg 62% of the time, and positive end-expiratory pressure was lower than recommended by the positive end-expiratory pressure/Fio2 grid 70% of the time. In multivariable analysis, tidal volume nonadherence was more common with severe pediatric acute respiratory distress syndrome, fewer PICU admissions/yr, non-European PICUs, higher delta pressure, corticosteroid use, and pressure control mode. Adherence was associated with underweight stature and cuffed endotracheal tubes. In multivariable analysis, positive end-expiratory pressure/Fio2 grid nonadherence was more common with higher pediatric acute respiratory distress syndrome severity, ventilator decisions made primarily by the attending physician, pre-ICU cardiopulmonary resuscitation, underweight stature, and age less than 2 years. Adherence was associated with respiratory therapist involvement in ventilator management and longer time from pediatric acute respiratory distress syndrome diagnosis. Higher nonadherence to tidal volume and positive end-expiratory pressure recommendations were independently associated with higher mortality and longer duration of ventilation after adjustment for confounding variables. In stratified analyses, these associations were primarily influenced by children with severe pediatric acute respiratory distress syndrome. CONCLUSIONS: Nonadherence to lung-protective ventilation principles is common in pediatric acute respiratory distress syndrome and may impact outcome. Modifiable factors exist that may improve adherence.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,002 | 0,007 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,001 |
| Méta-épidémiologie (sens large) | 0,002 | 0,000 |
| Bibliométrie | 0,001 | 0,002 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».