Non stationary combination for the simulation of time-varying flow rates in closed-loop ground heat exchangers
Notice bibliographique
Résumé
<p>Ground source heat pump systems are among the most energy-efficient heating and cooling technologies. Their performance is strongly related to the accuracy of the ground heat exchanger sizing, hence requiring the forecast of the system’s temperature evolution in response to the anticipated thermal loads. Through this process, simulation techniques that make use of the superposition principle are commonly used to reduce the computational burden. In their current state, these techniques are however only suitable for addressing linear and stationary problems and do not apply to fundamental non stationary situations related to ground source heat pumps operation that involve time-variant parameters.</p><p>The present work addresses this issue by introducing a novel method based on the principle of superposition that tackles the fast evaluation of the temperature of a closed-loop ground heat exchanger operating with a dynamic heat load as well as time-variant circulation flow rates. The developed method relies on the non stationary combination, a technique borrowed from the field of seismic data processing. This technique achieves discontinuous transitions of convolution products that can be smoothened near transition times by realizing a linear interpolation over the duration of the fluid residence time.</p><p>The accuracy and efficiency of the proposed method are verified by comparing its results with those provided by reference 3D finite-elements models developed in the Comsol Multiphysics environment. For this purpose, comparative simulations<strong> </strong>representing the non stationary operation of a closed-loop system having time-variant circulation flow rates are conducted. The case of a single well is first investigated, followed by a borefield of eight wells to demonstrate the validity of the method in both scenarios.</p><p>Findings indicate that the proposed method can reproduce the reference results with a mean absolute error that is lower than 0.02 °C, and that it is faster than the numerical models by several orders of magnitude. These findings suggest that a broader range of operating scenarios can be handled by highly efficient simulation tools based on the superposition principle, which could foster the development of optimal operating strategies and lead to enhanced overall performances of ground source heat pump systems.</p>
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».