Acoustics and Heat Transfer Characteristics of Piezoelectric Driven Central Orifice Synthetic Jet Actuators
Notice bibliographique
Résumé
Growth in computational capacity combined with a decrease in the size of digital devices has led to increasing demand for more active and efficient cooling of electronics. In this study, an experimental investigation into two different sizes of central orifice Synthetic Jet Actuators (SJAs) is conducted to evaluate their heat transfer as well as noise generation characteristics. Two SJAs (40 mm and 20 mm) are examined, covering a distinct span of frequencies ranging from low to medium (<5500 Hz) in regards to the effect of SJA size over performance. The SJAs’ disk deflection, structural frequency, and jet exit velocity were measured to fully characterize the jet performance. The maximum Nusselt number for the largest SJA was 3 times more than the smallest SJA, where the evaluation of stroke length suggests no effective synthetic jet formation for the smallest SJA. The noise from the SJAs was measured in an anechoic chamber using three microphones, Fast Fourier Transform (FFT) of the sound pressure levels provide contributions to different tones in the resulting noise. 1/3 Octave Constant Percentage Bandwidth (CPB) analysis was performed to identify the frequency bands making the largest contribution to the noise. The largest SJA showed the highest heat transfer at acceptable noise levels during the operation below resonance frequency.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».