MétaCan
Menu
Retour à la cohorte
Enregistrement W3190991977 · doi:10.1097/corr.0000000000001909

How Large a Study Is Needed to Detect TKA Revision Rate Reductions Attributable to Robotic or Navigated Technologies? A Simulation-based Power Analysis

2021· article· en· W3190991977 sur OpenAlexaff
Matthew Hickey, Carolyn Anglin, Bassam A. Masri, Antony J. Hodgson

Notice bibliographique

RevueClinical Orthopaedics and Related Research · 2021
Typearticle
Langueen
DomaineMedicine
ThématiqueTotal Knee Arthroplasty Outcomes
Établissements canadiensUniversity of CalgaryUniversity of British Columbia
Organismes subventionnairesnon disponible
Mots-clésMedicineRandomized controlled trialSurvivorship curveComparative effectiveness researchPsychological interventionClinical trialCohortCohort studyArthroplastyPhysical therapyMedical physicsPhysical medicine and rehabilitationSurgeryPopulationAlternative medicine

Résumé

récupéré en direct d'OpenAlex

BACKGROUND: Robotic and navigated TKA procedures have been introduced to improve component placement precision in the hope of improving implant survivorship and other clinical outcomes. Although numerous comparative studies have shown enhanced precision and accuracy in placing components, most comparative studies have not shown that such interventions result in improved implant survival. Given what we know about effect sizes from large arthroplasty registries, large cohort studies, and large randomized controlled trials (RCTs), we wondered how large randomized trials would need to be to detect such small differences, and if the number is very high, what that would tell us about the value of these treatments for preventing revision surgery. QUESTIONS/PURPOSES: In this simulation study, we asked: Given that survivorship differences between technology-assisted TKA (TA-TKA, which we defined as either navigated or robot-assisted TKA) and conventional TKA are either small or absent based on large arthroplasty registries, large cohort studies, and large RCTs, how large would randomized trials need to be to detect small differences between TA-TKA and conventional TKA if they exist, and how long would the follow-up period need to be to have a reasonable chance to detect those differences? METHODS: We used estimated effect sizes drawn from previous clinical and registry studies, combined with estimates of the accuracy and precision of various navigation and robotic systems, to model and simulate the likely outcomes of potential comparative clinical study designs. To characterize the ranges of patients enrolled and general follow-up times associated with traditional RCT studies, we conducted a structured search of previously published studies evaluating the effect of robotics and navigation on revision rates compared with that of conventional TKA. The structured search of the University of British Columbia's library database (which automatically searches medical publication databases such as PubMed, Embase, Medline, and Web of Science) and subsequent searching through included studies' reference lists yielded 103 search results. Only clinical studies assessing implant survival differences between patient cohorts of TA-TKA and conventional TKA were included. Studies analyzing registry data, using cadaver specimens, assessing revision TKA, conference proceedings, and preprint services were excluded. Twenty studies met all our inclusion criteria, but only one study reported a statistically significant difference between the conventional and robotic or navigated groups. Next, we generated a large set of patients with simulated TKA (1.5 million), randomly assigning each simulated patient a set of patient-specific factors (age at the index surgery, gender, and BMI) drawn from data from registries and published information. We divided this set of simulated procedures into four groups, each associated with a coronal alignment precision reported for different types of surgical procedures, and randomly assigned each patient an overall coronal alignment consistent with their group's precision. TA procedures were modeled based on the alignment precision that an intervention could deliver, regardless of whether the technology used was navigation- or robot-assisted. To evaluate the power associated with using different cohort sizes, we ran a Monte Carlo simulation generating 3000 simulated populations that were drawn (with replacement) from the large set of simulated patients with TKA. We simulated the time to revision for aseptic loosening for each patient, computed the corresponding Kaplan-Meier survival curves, and applied a log-rank test to each study for statistical differences in revision rates at concurrent follow-up timepoints (1-25 years). From each simulation associated with a given cohort size, we determined the percentage of simulated studies that found a statistically significant difference at each follow-up interval. For each alternative precision, we then also calculated the expected reduction in revision rates (effect size) attributable to TA-TKA intervention and the number needed to treat (NNT) using TA-TKA to prevent one revision at 2, 5, 10, and 15 years after index surgery for the entire set of Kaplan-Meier survival analyses. RESULTS: The results from our simulation found survivorship differences favoring TA-TKA ranging from 1.4% to 2.0% at 15 years of follow-up. Comparative studies would need to enroll between 2500 and 4000 patients in each arm of the study, depending on the precision of the navigated or robotic procedure, to have an 80% chance of showing this reduction in revision rates at 15 years of follow-up. For the highest precision simulated intervention, the NNT using TA-TKA to prevent one revision was 1000 at 2 years, 334 at 5 years, 100 at 10 years, and 50 at 15 years post-index surgery. CONCLUSION: Based on these simulations, it appears that TA-TKA interventions could potentially result in a relative reduction in revision rates as large as 27% (from 7.5% down to about 5.5% at 15 years for the intervention with the most precise coronal alignment); however, since this 2% absolute reduction in revision rates is relatively small in comparison with the baseline success rate of TKA and would not be realized until 15 years after the index surgery, traditional RCT studies would require excessively large numbers of patients to be enrolled and excessively long follow-up times to demonstrate whether such a reduction actually exists. CLINICAL RELEVANCE: Given that the NNTs to avoid revisions at various time points are predicted to be high, it would require correspondingly low system costs to justify broad adoption of TA-TKA based on avoided revision costs alone, though we speculate that technology assistance could perhaps prove to be cost effective in the care of patients who are at an elevated risk of revision.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction machine sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.

score de la tête « metaresearch » (Codex)0,281
score de la tête « metaresearch » (Gemma)0,467
Version: metacan-v3-hybrid-931329e0061cStatut de validation: machine_predicted_unvalidated
Catégories candidatesMétarecherche
Catégories consensuellesMétarecherche
DomaineSignal candidat: Méthodes · Signal consensuel: aucune
Devis d'étudeSignal candidat: Simulation ou modélisation · Signal consensuel: Simulation ou modélisation
GenreSignal candidat: Empirique · Signal consensuel: aucune
Score de désaccord entre enseignants0,719
Score d'incertitude au seuil0,887

Scores du classifieur distillé par catégorie (deux têtes)

CatégorieCodexGemma
Métarecherche0,2810,467
Méta-épidémiologie (sens strict)0,0010,001
Méta-épidémiologie (sens large)0,0040,013
Bibliométrie0,0020,001
Études des sciences et des technologies0,0010,003
Communication savante0,0030,004
Science ouverte0,0040,003
Intégrité de la recherche0,0030,003
Charge utile insuffisante (le modèle a refusé de juger)0,0060,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,105
Tête enseignante GPT0,458
Écart entre enseignants0,353 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; l’étiquette directe de Gemma et le classifieur distillé Codex s’accordent sur ce qui est montré ici.

Devis d'étudeSimulation ou modélisation
DomaineMéthodes
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations23
Publié2021
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueClinical Orthopaedics and Related ResearchMême sujetTotal Knee Arthroplasty OutcomesTravaux en français237 207