(Corrosion Division Morris Cohen Graduate Student Award Address) Galvanic Corrosion of Copper-Coated Carbon Steel for Used Nuclear Fuel Containers
Notice bibliographique
Résumé
Carbon steel vessels coated with ∼3 mm of Cu have been proposed for the permanent disposal of used nuclear fuel in a deep geological repository (DGR) in Canada. In the event that a container is emplaced in the DGR with an undetected defect in the Cu coating that exposes the steel substrate, galvanically accelerated corrosion of steel is, in principle, possible. To investigate this scenario, the progression of steel corrosion at the base of novel simulated through-coating defects was monitored electrochemically and imaged non-destructively using X-ray micro-computed tomography (micro-CT) as a function of time, O 2 availability (including anoxic conditions), and coating method (cold spray deposition (with and without heat treatment) and electrodeposition). The corrosion products and surface damage were analyzed using Raman spectroscopy and scanning electron microscopy (SEM)/energy dispersive X-ray spectroscopy (EDX). These analyses showed how the corrosion damage to steel evolved over time and how it was affected by the method used to coat steel with Cu and the amount of O 2 available. The results showed that steel exposed at the base of a through-Cu coating defect corroded and became covered by corrosion products, while there was no visible loss of Cu. The supply of O 2 to the sample surface governed the corrosion rate, while the distribution of damage to steel at the base of the defect depended on the Cu coating method and the resulting quality of the Cu/steel interface. Cold spray Cu-coated steel specimens exhibited a radial spread of corrosion along the Cu/steel interface, while electrodeposited Cu/steel specimens experienced preferential interfacial corrosion in the direction in which the steel substrate was machined prior to the electrodeposition of Cu. An example of the progression of corrosion observed by micro-CT is shown in Figure 1. Less extensive corrosion along the Cu/steel interface was observed on samples that were shown by electron backscatter diffraction (EBSD) and adhesion tests to have a less stressed, more uniform, and more well-adhered interface. However, less extensive corrosion was typically at the expense of deeper penetration into the steel. In the absence of O 2 , the quality of the Cu/steel interface greatly affected both the overall amount of corrosion damage to steel and the distribution of damage. The corrosion rates were significantly lower under anoxic conditions than under oxic conditions, and tended to decrease over time. The influence of a wide range of cathode:anode area ratios and Cl − concentrations, and the availability of O 2 , was evaluated by monitoring the galvanic current passing between separate Cu and steel electrodes, connected through a zero-resistance ammeter (ZRA), and the galvanic potential of the couple. The galvanic corrosion of steel was most severe when it was exposed to air-sparged solution with a moderate [Cl − ] as part of the couple with the largest Cu:steel area ratio. Figure 1
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,001 | 0,000 |
| Études des sciences et des technologies | 0,001 | 0,000 |
| Communication savante | 0,001 | 0,001 |
| Science ouverte | 0,001 | 0,001 |
| Intégrité de la recherche | 0,001 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,293 | 0,131 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».