Modeling and Design of Parallel LCC-VSC Interlinking Converters’ Unified Controller in AC/DC Network
Notice bibliographique
Résumé
While both line-commutated converters (LCCs) and voltage-source converters (VSCs) have been adopted in ac/dc grids, they are mostly used individually despite some point-to-point dc transmission. The combination of both technologies as a single interlinking converter (IC) unit in an ac/dc grid can bring advantages, such as capacity expansion, bidirectional power flow, reactive power support, and harmonics compensation. For such a parallel LCC-VSC unit, a suitable control scheme and careful control parameters’ design are important to ensure that the system can maintain the above advantages in different operation modes. In this article, the control scheme and parameter design for a parallel LCC-VSC unit for use in an ac/dc grid are conducted with a focus on capacity expansion scenario, where a unified control scheme that reserves most of the original LCC terminal’s control while also smoothly incorporates the VSC operation is considered. The operation states of a hybrid ac/dc network are modeled. The proposed unified control scheme is considered for each state for the stability study. Then, a set of control parameters for the unified control scheme suitable for all operation states with good dynamics and stability is designed. Real-time simulations and experiments are conducted to verify the design and study.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».