Do Adhesive Drapes Have an Effect on Infection Rates in Orthopaedic Surgery? A Systematic Review and Meta-Analysis
Notice bibliographique
Résumé
BACKGROUND: Adhesive surgical drapes are purported to reduce the rates of surgical site infection. Despite that, international surgical guidelines generally recommend against the use of such drapes; however, this is primarily based on nonorthopaedic evidence. QUESTIONS/PURPOSES: (1) Does the use of adhesive drapes decrease the risk of wound contamination? (2) Does intraoperative drape peeling (intentional or inadvertent) increase the risk of wound contamination? (3) Does the use of adhesive drapes decrease the risk of surgical site infection? METHODS: A systematic review of the MEDLINE and Embase databases was performed according to the Cochrane Handbook methods for randomized controlled trials (RCTs) published since 2000 and comparing adhesive drapes with controls. All databases were searched from inception to March 1, 2021. A pooled meta-analysis was performed, where possible. The Cochrane Risk of Bias Assessment Tool was used to assess risk of bias among the included studies. From among 417 search results, five eligible RCTs were identified and included, all of which were published between 2018 and 2020. There were a total of 2266 patients, with 1129 (49.8%) in the adhesive drape groups, and 1137 (50.2%) in the control groups. The studies included hip and knee surgery trials (n = 3 trials; 1020 patients in intervention groups and 1032 patients in control groups) as well as trials on shoulder arthroscopy (n = 1 trial; 65 patients in the intervention group and 61 patients in the control group) and lumbar spine surgery (n = 1 trial; 44 patients in each group). The data for all three outcomes (wound contamination, impact of intraoperative peeling, and surgical site infection) revealed low heterogeneity based on random-effects models (I2 = 14%, 0%, and 0%, respectively). RESULTS: Based on data from pooled wound swab culture results from four studies, a reduction in wound contamination was associated with the use of adhesive drapes (odds ratio 0.49 [95% CI 0.34 to 0.72]; p < 0.001). The available evidence was inconclusive to determine whether intraoperative drape peeling (intentional or inadvertent) influenced the risk of wound contamination. Three studies did not report on this outcome, one study found an increased infection rate with drape peel back, and another study found a reduced treatment effect of adhesive drapes when peel back occurred in a subgroup analysis. The two studies that analyzed surgical site infections reported no infections in either arm; therefore, we could not answer the question of whether adhesive drapes affect risk of surgical site infection. CONCLUSION: The findings of this review suggest that adhesive drapes, including those with antimicrobial properties, decrease the risk of wound contamination during orthopaedic procedures. In circumstances where drape adhesion is compromised and peel back occurs at the wound edge, there is an increased risk of wound contamination with the use of adhesive drapes. The best currently available evidence is indeterminate as to the effect of adhesive drapes on the risk of surgical site infections; however, if used, care should be taken to avoid or minimize drape peel back. LEVEL OF EVIDENCE: Level I, therapeutic study.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,017 | 0,045 |
| Méta-épidémiologie (sens strict) | 0,003 | 0,002 |
| Méta-épidémiologie (sens large) | 0,020 | 0,042 |
| Bibliométrie | 0,008 | 0,008 |
| Études des sciences et des technologies | 0,001 | 0,001 |
| Communication savante | 0,004 | 0,002 |
| Science ouverte | 0,002 | 0,002 |
| Intégrité de la recherche | 0,003 | 0,002 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,004 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».