MétaCan
Menu
Retour à la cohorte
Enregistrement W3200099356 · doi:10.7759/cureus.18113

The Designing, Testing, and Utility of a 3D-Printed Respirator: A Hospital's Journey Into Self-Sustainability During COVID-19

2021· article· en· W3200099356 sur OpenAlexaff
Aditya Lal Vallath, Ravisha More, Satyajeet Bhaskare, Sarabjeet Rattan, Ajinkya Athlye, Adheeth Praveen, Bindi S Patel, Vyom Richharia, Akshita Lalendran, Sudhir Patsute

Notice bibliographique

RevueCureus · 2021
Typearticle
Langueen
DomaineMedicine
ThématiqueInfection Control and Ventilation
Établissements canadiensGlycemic Index Laboratories
Organismes subventionnairesnon disponible
Mots-clésRespiratorPersonal protective equipmentCoronavirus disease 2019 (COVID-19)Health careEconomic shortageBusinessPandemicOperations managementMedical emergencyMedicineEngineeringInfectious disease (medical specialty)

Résumé

récupéré en direct d'OpenAlex

Objective The current global COVID-19 pandemic has disrupted supply chains and the production of essential goods and services. This includes personal protective equipment (PPE) kits, respirators, and other protective devices. Hence efforts were made to prototype and produce 3D-printed N95 respirators to fill the gap in supply. In addition, methods of sterilization were put into place for the respirators. As well as forming standard operating procedures. Methods With the use of vast open-source libraries and collaboration with engineers and doctors fighting the COVID-19 pandemic, respirator prototypes were produced with special consideration to the sizing to fit median facial sizes. Polymer plastics were mixed in various proportions to condition the respirator to be used by frontline workers in austere environments. Due to the shortage of medical-grade filter media, alternative sources were researched. Merv 13 and Merv 15 filters were selected due to their cheap costs, vast abundance, and proven filtration efficacy against particles of 0.03 microns. Studies conducted around the world have also shown its efficacy as an alternative to medical-grade air filter media. After developing standard operating procedures (SOPs) for sterilisation and respirator usage. Emergency approval was obtained and a limited number of healthcare workers were issued with this respirator (n=400). PPE kit satisfaction and self-efficacy scores were calculated from daily questionnaires during donning and doffing Results Qualitative fit-tests in all 400 healthcare workers matched those of a conventional N95 respirator. Almost all of the respondents in the PPE kit satisfaction responded positively. The self-efficacy score calculated from the general self-efficiency scale had an overall positive value, with the average score being 4.29. This demonstrated that the self-efficacy score was above average and indicated a high motivation to overcome obstacles and spend more time solving problems. The average self-efficacy score is defined between 2.5 - 3.5, and a low self-efficacy score is defined as a score below 2.5. Lastly, a regression analysis was done to test the correlation between PPE kit satisfaction and self-efficiency this demonstrated a positive correlation between PPE kit satisfaction using the 3D-printed respirator and self-efficacy (Slope: 0.416, Intercept: -1.066, R-value: 0.872, P-value: <0.01) Conclusions With supply chain disruptions and reduced or nonexistent supplies of essential medical goods. The need of a reusable, sterilisable, and efficient respirator has never been more evident. The materials used have made it sustain heavy use in austere environments. Studies have reported higher than average burnout rates in COVID-19-based healthcare workers. Studies have also shown that the rates of burnout are high in healthcare professionals without access to proper PPE kits in developing nations. This respirator was rated highly in PPE kit satisfaction and the self-efficacy score. Studies have demonstrated a correlation between high self-efficacy scores and low burnout rates in health care workers. There is also documented evidence of a positive correlation between high self-efficacy scores and general health. As the pandemic continues to evolve, so will the efforts to combat it, such as 3D printing. Interdisciplinary collaboration continues to drive our efforts to combat the pandemic and hopefully resolve it in the future.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction machine sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.

score de la tête « metaresearch » (Codex)0,004
score de la tête « metaresearch » (Gemma)0,006
Version: metacan-v3-hybrid-931329e0061cStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Expérimental (laboratoire) · Signal consensuel: aucune
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,004
Score d'incertitude au seuil0,020

Scores du classifieur distillé par catégorie (deux têtes)

CatégorieCodexGemma
Métarecherche0,0040,006
Méta-épidémiologie (sens strict)0,0010,000
Méta-épidémiologie (sens large)0,0000,000
Bibliométrie0,0000,000
Études des sciences et des technologies0,0010,001
Communication savante0,0020,001
Science ouverte0,0010,002
Intégrité de la recherche0,0010,001
Charge utile insuffisante (le modèle a refusé de juger)0,0020,001

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,025
Tête enseignante GPT0,313
Écart entre enseignants0,288 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeExpérimental (laboratoire)
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations3
Publié2021
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueCureusMême sujetInfection Control and VentilationTravaux en français237 207