What Are the Long-term Surgical Outcomes of Compressive Endoprosthetic Osseointegration of the Femur with a Minimum 10-year Follow-up Period?
Notice bibliographique
Résumé
BACKGROUND: Endoprosthetic reconstruction after oncologic resection of bone tumors requires stable fixation between the prosthesis and residual host bone. Compressive osseointegration has been developed as an alternative to traditional stemmed implants to address the challenges and complications of achieving this fixation. Sufficient time has now passed from the advent of compressive implants to allow for an assessment of the intermediate-term and long-term results of this form of fixation. QUESTIONS/PURPOSES: At a minimum follow-up of 10 years after implantation of a compressive osseointegration device for oncologic reconstruction: (1) What is the risk of periprosthetic fracture, aseptic loosening, or implant breakage resulting in revision surgery for endoprosthesis removal? (2) What is the long-term cortical response at the host-endoprosthesis interface as visualized on plain radiographs? METHODS: A single-center, retrospective study was performed between 2002 and 2010, in which 110 patients with primary bone sarcoma of the proximal or distal femur were considered for oncologic resection and reconstruction. Patients were considered for a compressive osseointegration endoprosthesis if they were 50 years of age or younger, had not previously received femoral radiation, had no metabolic disease impairing bone healing, were not diagnosed with metastatic disease, and had life expectancy greater than six months. Of the 110 patients, 25 were treated with a compressive osseointegration implant of the proximal or distal femur, and 85 patients were treated with conventional stemmed implants or amputation because of older age, advanced disease, metabolic comorbidities, inability to tolerate a nonweightbearing postoperative period, or in the case of rotationplasty, patient preference. All patients who received this device during the period of study were considered eligible for inclusion in this review. The median (range) age was 18 years (7 to 50), and 13 of 25 patients were men. Five patients died of disease before the minimum follow-up duration of 10 years; two underwent amputation due to local recurrence and three died with the implant in situ, leaving 20 patients for complete analysis. Median follow-up was 144 months, and all 20 surviving patients had a minimum follow-up of 10 years (121 to 230 months). The primary endpoint was reoperation and implant removal for periprosthetic fracture, aseptic loosening, or mechanical breakage of any component of the compressive device in the endoprosthesis. In final analysis, death was considered a competing event to revision surgery, and cumulative incidence was reported after competing-event analysis. A secondary aim was radiographic evaluation of the host-implant interface to assess the long-term cortical response to compressive osseointegration. RESULTS: Spindle fracture or loosening was noted in three patients, and the remaining 17 patients maintained the compression device until the final follow-up. The risk of reoperation for aseptic loosening, periprosthetic fracture, or mechanical breakage of the implant using a competing risks estimator was 12% at 10 years (95% CI 0% to 26%). These complications occurred within 29 months of the index surgery; no patients had implant loosening or mechanical breakdown after this initial period. On radiographic assessment, 14 patients demonstrated cortical hypertrophy of the bone-implant interface, six patients had maintenance of the native cortical contour, and no patients had cortical atrophy or narrowing at the implant interface.Conclusion Long-term follow-up in patients with compressive osseointegrative endoprosthetic devices demonstrated no late revisions because of periprosthetic fracture, aseptic loosening, or implant breakage in this cohort with a minimum 10-year follow-up. There was no evidence of late-onset cortical atrophy or stress shielding at the host-implant interface. This study supports the long-term stability of the interface between host bone and the endoprosthesis in compressive osseointegration devices. LEVEL OF EVIDENCE: Level IV, therapeutic study.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,004 | 0,014 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,002 |
| Bibliométrie | 0,002 | 0,001 |
| Études des sciences et des technologies | 0,001 | 0,001 |
| Communication savante | 0,001 | 0,001 |
| Science ouverte | 0,001 | 0,001 |
| Intégrité de la recherche | 0,001 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».