Simultaneous measurements of velocity, gas concentration, and temperature by way of thermal-anemometry-based probes
Notice bibliographique
Résumé
Abstract Many natural and engineering flows transport more than one scalar. Moreover, to study the scalar mixing therein, knowledge of the velocity field is also essential. For this reason, the present work describes the development of a three-wire thermal-anemometry-based probe to simultaneously measure velocity, helium concentration, and temperature in turbulent flows. It is first demonstrated, both theoretically and experimentally, that the temperature measured by a cold-wire thermometer is effectively insensitive to helium concentration. Then, building on recent work by Hewes and Mydlarski (2021 Meas. Sci. Technol. 32 105305), which pertains to the design of interference probes (i.e. thermal-anemometry-based probes used to measure velocity and gas concentration), a novel temperature compensation technique is proposed to extend their use to non-isothermal flows. The performance of the compensation technique is validated in turbulent coaxial jets by combining the cold-wire thermometer and interference probe to form a three-wire probe. Given that the three-wire probe can be employed to obtain simultaneous measurements of velocity and multiple scalars, it can therefore be used investigate phenomena such as multi-scalar mixing, including differential diffusion.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».