MétaCan
Menu
Retour à la cohorte
Enregistrement W3207181646 · doi:10.2196/33049

Differential Biases and Variabilities of Deep Learning–Based Artificial Intelligence and Human Experts in Clinical Diagnosis: Retrospective Cohort and Survey Study

2021· article· en· W3207181646 sur OpenAlexvenueno aff
Dongchul Cha, Chongwon Pae, Se A Lee, Gina Na, Young Kyun Hur, Ho Young Lee, Ara Cho, Young Joon Cho, Sang Gil Han, Sung Huhn Kim, Jae Young Choi, Hae‐Jeong Park

Notice bibliographique

RevueJMIR Medical Informatics · 2021
Typearticle
Langueen
DomaineMedicine
ThématiqueCOVID-19 diagnosis using AI
Établissements canadiensnon disponible
Organismes subventionnairesYonsei University College of MedicineMinistry of Science and ICT, South KoreaNational Research Foundation of KoreaMinistry of Science, ICT and Future PlanningInje UniversityYonsei UniversityNational Research Foundation
Mots-clésArtificial intelligenceMedicineMachine learningPopulationTest (biology)Medical diagnosisMedical physicsComputer sciencePathology

Résumé

récupéré en direct d'OpenAlex

BACKGROUND: Deep learning (DL)-based artificial intelligence may have different diagnostic characteristics than human experts in medical diagnosis. As a data-driven knowledge system, heterogeneous population incidence in the clinical world is considered to cause more bias to DL than clinicians. Conversely, by experiencing limited numbers of cases, human experts may exhibit large interindividual variability. Thus, understanding how the 2 groups classify given data differently is an essential step for the cooperative usage of DL in clinical application. OBJECTIVE: This study aimed to evaluate and compare the differential effects of clinical experience in otoendoscopic image diagnosis in both computers and physicians exemplified by the class imbalance problem and guide clinicians when utilizing decision support systems. METHODS: We used digital otoendoscopic images of patients who visited the outpatient clinic in the Department of Otorhinolaryngology at Severance Hospital, Seoul, South Korea, from January 2013 to June 2019, for a total of 22,707 otoendoscopic images. We excluded similar images, and 7500 otoendoscopic images were selected for labeling. We built a DL-based image classification model to classify the given image into 6 disease categories. Two test sets of 300 images were populated: balanced and imbalanced test sets. We included 14 clinicians (otolaryngologists and nonotolaryngology specialists including general practitioners) and 13 DL-based models. We used accuracy (overall and per-class) and kappa statistics to compare the results of individual physicians and the ML models. RESULTS: Our ML models had consistently high accuracies (balanced test set: mean 77.14%, SD 1.83%; imbalanced test set: mean 82.03%, SD 3.06%), equivalent to those of otolaryngologists (balanced: mean 71.17%, SD 3.37%; imbalanced: mean 72.84%, SD 6.41%) and far better than those of nonotolaryngologists (balanced: mean 45.63%, SD 7.89%; imbalanced: mean 44.08%, SD 15.83%). However, ML models suffered from class imbalance problems (balanced test set: mean 77.14%, SD 1.83%; imbalanced test set: mean 82.03%, SD 3.06%). This was mitigated by data augmentation, particularly for low incidence classes, but rare disease classes still had low per-class accuracies. Human physicians, despite being less affected by prevalence, showed high interphysician variability (ML models: kappa=0.83, SD 0.02; otolaryngologists: kappa=0.60, SD 0.07). CONCLUSIONS: Even though ML models deliver excellent performance in classifying ear disease, physicians and ML models have their own strengths. ML models have consistent and high accuracy while considering only the given image and show bias toward prevalence, whereas human physicians have varying performance but do not show bias toward prevalence and may also consider extra information that is not images. To deliver the best patient care in the shortage of otolaryngologists, our ML model can serve a cooperative role for clinicians with diverse expertise, as long as it is kept in mind that models consider only images and could be biased toward prevalent diseases even after data augmentation.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,002
score de la tête « metaresearch » (Gemma)0,013
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesMétarecherche
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Observationnel · Signal consensuel: Observationnel
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,012
Score d'incertitude au seuil0,995

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0020,013
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0010,000
Bibliométrie0,0000,000
Études des sciences et des technologies0,0000,001
Communication savante0,0000,000
Science ouverte0,0000,000
Intégrité de la recherche0,0000,001
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,087
Tête enseignante GPT0,411
Écart entre enseignants0,324 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.

Devis d'étudeObservationnel
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations14
Publié2021
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueJMIR Medical InformaticsMême sujetCOVID-19 diagnosis using AITravaux en français237 207