Fecal Leukocyte Esterase, an Alternative Biomarker to Fecal Calprotectin in Inflammatory Bowel Disease: A Pilot Series
Notice bibliographique
Résumé
Background and AimsFecal calprotectin (FC) is a noninvasive biomarker used in inflammatory bowel disease (IBD) management and risk stratification of nonspecific gastrointestinal symptoms. Leukocyte esterase is an inexpensive and widely available point-of-care inflammatory marker present on urinalysis test strips. We aim to assess the diagnostic accuracy of fecal leukocyte esterase (FLE) relative to FC and endoscopy and demonstrate its use as an alternative biomarker for IBD.MethodsIn this prospective cohort study, 70 patients who had FC ordered as part of standard clinical care also received FLE testing. FLE levels were compared with various FC cutoff values and endoscopy and pathology findings as the gold standard.ResultsAs the FC cutoff increased from 50 to 500 μg/g, FLE sensitivity increased from 67% to 95% while the specificity decreased from 86% to 76%. The area under the receiver operating characteristic (AUROC) curve increased from 0.79 to 0.90. An FLE of ≥1+ had the best test characteristics. Among patients who underwent endoscopic evaluation, FLE demonstrated an identical sensitivity (75%) and specificity (86%) to FC in predicting endoscopic inflammation. AUROC was 0.80 for FLE and 0.85 for FC with an optimal cutoff of ≥2+ and 301 μg/g, respectively. When used to distinguish between patients with active IBD and no/inactive IBD, FLE had a sensitivity of 84% and specificity of 90%, comparable with the 84% and 83%, respectively, of FC. AUROC was 0.88 for FLE and 0.91 for FC with an optimal cutoff of ≥2+ and 145 μg/g, respectively.ConclusionFLE demonstrates adequate correlation and comparable accuracy with FC in predicting endoscopic inflammation and distinguishing between patients with active vs inactive IBD. Fecal calprotectin (FC) is a noninvasive biomarker used in inflammatory bowel disease (IBD) management and risk stratification of nonspecific gastrointestinal symptoms. Leukocyte esterase is an inexpensive and widely available point-of-care inflammatory marker present on urinalysis test strips. We aim to assess the diagnostic accuracy of fecal leukocyte esterase (FLE) relative to FC and endoscopy and demonstrate its use as an alternative biomarker for IBD. In this prospective cohort study, 70 patients who had FC ordered as part of standard clinical care also received FLE testing. FLE levels were compared with various FC cutoff values and endoscopy and pathology findings as the gold standard. As the FC cutoff increased from 50 to 500 μg/g, FLE sensitivity increased from 67% to 95% while the specificity decreased from 86% to 76%. The area under the receiver operating characteristic (AUROC) curve increased from 0.79 to 0.90. An FLE of ≥1+ had the best test characteristics. Among patients who underwent endoscopic evaluation, FLE demonstrated an identical sensitivity (75%) and specificity (86%) to FC in predicting endoscopic inflammation. AUROC was 0.80 for FLE and 0.85 for FC with an optimal cutoff of ≥2+ and 301 μg/g, respectively. When used to distinguish between patients with active IBD and no/inactive IBD, FLE had a sensitivity of 84% and specificity of 90%, comparable with the 84% and 83%, respectively, of FC. AUROC was 0.88 for FLE and 0.91 for FC with an optimal cutoff of ≥2+ and 145 μg/g, respectively. FLE demonstrates adequate correlation and comparable accuracy with FC in predicting endoscopic inflammation and distinguishing between patients with active vs inactive IBD.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».