MétaCan
Menu
Retour à la cohorte
Enregistrement W3208632305 · doi:10.33137/cpoj.v5i1.36744

EXPLORATION OF VIBROTACTILE BIOFEEDBACK STRATEGIES TO INDUCE STANCE TIME ASYMMETRIES

2021· article· en· W3208632305 sur OpenAlexafffundvenueabout
Rafael Escamilla-Nunez, Harry Sivasambu, Jan Andrysek

Notice bibliographique

RevueCanadian Prosthetics & Orthotics Journal · 2021
Typearticle
Langueen
DomaineHealth Professions
ThématiqueBalance, Gait, and Falls Prevention
Établissements canadiensHolland Bloorview Kids Rehabilitation HospitalUniversity of Toronto
Organismes subventionnairesNatural Sciences and Engineering Research Council of CanadaÖssur
Mots-clésGaitBiofeedbackSymmetry (geometry)Physical medicine and rehabilitationAsymmetryPsychologyComputer scienceMathematicsPhysicsMedicineGeometry

Résumé

récupéré en direct d'OpenAlex

BACKGROUND: Gait symmetry is the degree of equality of biomechanical parameters between limbs within a gait cycle. Human gait is highly symmetrical; however, in the presence of pathology, gait often lacks symmetry. Biofeedback (BFB) systems have demonstrated the potential to reduce gait asymmetry, improve gait function, and benefit overall long-term musculoskeletal health. OBJECTIVE(S): The aim of this study was to develop a BFB system and evaluate three unique BFB strategies, including bidirectional control – constant vibration (BC), bidirectional control – variable vibration (BV), and unidirectional control – variable vibration (UV) relevant to gait symmetry. The assessed feedback strategies were a combination of vibration frequency/amplitude levels, vibration thresholds, and vibrotactile stimuli from one and two vibrating motors (tactors). Learning effect and short-term retention were also assessed. METHODOLOGY: Testing was performed using a custom BFB system that induces stance time asymmetries to modulate temporal gait symmetry. The BFB system continuously monitors specific gait events (heel-strike and toe-off) and calculates the symmetry ratio, based on the stance time of both limbs to provide real-time biomechanical information via the vibrating motors. Overall walking performance of ten (n=10) able-bodied individuals (age 24.8 ± 4.4 years) was assessed via metrics of symmetry ratio, symmetry ratio error, walking speed, and motor's vibration percentages. FINDINGS: All participants utilized BFB somatosensory information to modulate their symmetry ratio. UV feedback produced a greater change in symmetry ratio, and it came closer to the targeted symmetry ratio. Learning or short-term retention effects were minimal. Walking speeds were reduced with feedback compared to no feedback; however, UV walking speeds were significantly faster compared to BV and BC. CONCLUSION: The outcomes of this study provide new insights into the development and implementation of feedback strategies for gait retraining BFB systems that may ultimately benefit individuals with pathological gait. Future work should assess longer-term use and long-term learning and retention effects of BFB systems in the populations of interest. Layman's Abstract Healthy walking is usually highly symmetrical with the same movements occurring on both sides of the body. However, certain disorders can cause abnormal and asymmetrical walking movements. Biofeedback can improve the movements during walking. This study used a custom biofeedback system to test three ways of applying biofeedback including having one and two motors that vibrated in unique ways. The biofeedback system was set up to guide participants to change their normal walking pattern to be less symmetrical. Walking movements of ten young able-bodied individuals were measured while walking with the biofeedback system. The results showed a change in walking symmetry for all participants. Using a single vibrating motor resulted in the greatest changes in walking symmetry. The changes in walking symmetry occurred only when using biofeedback, and walking patterns quickly returned to normal when the biofeedback was turned off. Overall, all feedback methods caused the users to walk slower than their typical walking speed. These findings provide important new information about the changes in walking caused by different biofeedback methods. Future work should evaluate long-term effects of biofeedback methods in the populations of interest. Article PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/36744/28677 How To Cite: Escamilla-Nunez R, Sivasambu H, Andrysek J. Exploration of vibrotactile biofeedback strategies to induce stance time asymmetries. Canadian Prosthetics & Orthotics Journal. 2022; Volume 5, Issue 1, No.2. https://doi.org/10.33137/cpoj.v5i1.36744 Corresponding Author: Rafael Escamilla-Nunez, Institute of Biomedical Engineering, University of Toronto, Toronto, Canada.E-Mail: rafael.escamilla@mail.utoronto.caORCID ID: https://orcid.org/0000-0002-2739-878X

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,001
score de la tête « metaresearch » (Gemma)0,000
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Sans objet · Signal consensuel: aucune
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,406
Score d'incertitude au seuil0,982

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0010,000
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0000,000
Bibliométrie0,0000,001
Études des sciences et des technologies0,0010,000
Communication savante0,0000,001
Science ouverte0,0000,000
Intégrité de la recherche0,0000,001
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,034
Tête enseignante GPT0,335
Écart entre enseignants0,301 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeSans objet
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations7
Publié2021
Routes d'admission4
Résumé présentoui

Explorer davantage

Même revueCanadian Prosthetics & Orthotics JournalMême sujetBalance, Gait, and Falls PreventionTravaux en français237 207