Stereotactic body radiotherapy for intramedullary metastases: a retrospective series at the Oscar Lambret center and a systematic review
Notice bibliographique
Résumé
BACKGROUND: Intramedullary metastasis (IMM) is a rare disease with poor prognosis. The incidence of IMMs has increased, which has been linked to improved systemic treatment in many cancers. Surgery and/or radiotherapy are the most commonly used treatments; only small-sample retrospective studies and case reports on stereotactic body radiotherapy (SBRT) have reported acceptable results in terms of local control and clinical improvement, with no reported toxicity. Thus, we performed this monocentric retrospective study on five cases treated with SBRT for IMMs, which we supplemented with a systematic review of the literature. METHODS: We included all patients treated for IMM with SBRT. The target tumor volume, progression-free survival, prescription patterns in SBRT, survival without neurological deficit, neurological functional improvement after treatment, and overall survival were determined. RESULTS: Five patients treated with a median dose of 30 Gy in a median number of fractions of 5 (prescribed at a median isodose of 86%) included. The median follow-up duration was 23 months. Two patients showed clinical improvement. Three patients remained stable. Radiologically, 25% of patients had complete response and 50% had stable disease. No significant treatment-related toxicity was observed. CONCLUSION: SBRT appears to be a safe, effective, and rapid treatment option for palliative patients.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,000 |
| Méta-épidémiologie (sens large) | 0,005 | 0,001 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».