Continuous Noninvasive Remote Automated Blood Pressure Monitoring With Novel Wearable Technology: A Preliminary Validation Study

2021· article· en· W3213490522 sur OpenAlexafffundvenue
Michael McGillion, Nazari Dvirnik, Stephen Yang, Emilie P. Belley‐Côté, André Lamy, Richard Whitlock, Maura Marcucci, Flávia K. Borges, Emmanuelle Duceppe, Carley Ouellette, Marissa Bird, Sandra Carroll, David Conen, Jean‐Éric Tarride, Prathiba Harsha, Ted Scott, Amber Good, Krysten Gregus, Pamela J. Benoit, Julian Owen, Valerie Harvey, Elizabeth Peter, Jeremy Petch, Jessica Vincent, Michelle M. Graham, P.J. Devereaux

Notice bibliographique

RevueJMIR mhealth and uhealth · 2021
Typearticle
Langueen
DomaineMedicine
ThématiqueHemodynamic Monitoring and Therapy
Établissements canadiensUniversity of TorontoHamilton Health SciencesUniversity of AlbertaPopulation Health Research InstituteUniversité de MontréalMcGill UniversityMcMaster University
Organismes subventionnairesHeart and Stroke Foundation of Canada
Mots-clésSupine positionContinuous monitoringWearable computerMedicineVital signsBlood pressureLaptopIntensive care unitIntensive careComputer scienceBiomedical engineeringSurgeryIntensive care medicineEmbedded systemEngineeringRadiology

Résumé

récupéré en direct d'OpenAlex

BACKGROUND: Wearable continuous monitoring biosensor technologies have the potential to transform postoperative care with early detection of impending clinical deterioration. OBJECTIVE: Our aim was to validate the accuracy of Cloud DX Vitaliti continuous vital signs monitor (CVSM) continuous noninvasive blood pressure (cNIBP) measurements in postsurgical patients. A secondary aim was to examine user acceptance of the Vitaliti CVSM with respect to comfort, ease of application, sustainability of positioning, and aesthetics. METHODS: Included participants were ≥18 years old and recovering from surgery in a cardiac intensive care unit (ICU). We targeted a maximum recruitment of 80 participants for verification and acceptance testing. We also oversampled to minimize the effect of unforeseen interruptions and other challenges to the study. Validation procedures were according to the International Standards Organization (ISO) 81060-2:2018 standards for wearable, cuffless blood pressure (BP) measuring devices. Baseline BP was determined from the gold-standard ICU arterial catheter. The Vitaliti CVSM was calibrated against the reference arterial catheter. In static (seated in bed) and supine positions, 3 cNIBP measurements, each 30 seconds, were taken for each patient with the Vitaliti CVSM and an invasive arterial catheter. At the conclusion of each test session, captured cNIBP measurements were extracted using MediCollector BEDSIDE data extraction software, and Vitaliti CVSM measurements were extracted to a secure laptop through a cable connection. The errors of these determinations were calculated. Participants were interviewed about device acceptability. RESULTS: The validation analysis included data for 20 patients. The average times from calibration to first measurement in the static position and to first measurement in the supine position were 133.85 seconds (2 minutes 14 seconds) and 535.15 seconds (8 minutes 55 seconds), respectively. The overall mean errors of determination for the static position were -0.621 (SD 4.640) mm Hg for systolic blood pressure (SBP) and 0.457 (SD 1.675) mm Hg for diastolic blood pressure (DBP). Errors of determination were slightly higher for the supine position, at 2.722 (SD 5.207) mm Hg for SBP and 2.650 (SD 3.221) mm Hg for DBP. The majority rated the Vitaliti CVSM as comfortable. This study was limited to evaluation of the device during a very short validation period after calibration (ie, that commenced within 2 minutes after calibration and lasted for a short duration of time). CONCLUSIONS: We found that the Cloud DX's Vitaliti CVSM demonstrated cNIBP measurement in compliance with ISO 81060-2:2018 standards in the context of evaluation that commenced within 2 minutes of device calibration; this device was also well-received by patients in a postsurgical ICU setting. Future studies will examine the accuracy of the Vitaliti CVSM in ambulatory contexts, with attention to assessment over a longer duration and the impact of excessive patient motion on data artifacts and signal quality. TRIAL REGISTRATION: ClinicalTrials.gov NCT03493867; https://clinicaltrials.gov/ct2/show/NCT03493867.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction machine sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.

score de la tête « metaresearch » (Codex)0,005
score de la tête « metaresearch » (Gemma)0,007
Version: metacan-v3-hybrid-931329e0061cStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Expérimental (laboratoire) · Signal consensuel: aucune
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,005
Score d'incertitude au seuil0,027

Scores du classifieur distillé par catégorie (deux têtes)

CatégorieCodexGemma
Métarecherche0,0050,007
Méta-épidémiologie (sens strict)0,0010,000
Méta-épidémiologie (sens large)0,0010,001
Bibliométrie0,0000,000
Études des sciences et des technologies0,0000,001
Communication savante0,0010,001
Science ouverte0,0010,001
Intégrité de la recherche0,0010,001
Charge utile insuffisante (le modèle a refusé de juger)0,0020,001

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,030
Tête enseignante GPT0,350
Écart entre enseignants0,320 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeExpérimental (laboratoire)
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations16
Publié2021
Routes d'admission3
Résumé présentoui

Explorer davantage

Même revueJMIR mhealth and uhealth→Même sujetHemodynamic Monitoring and Therapy→Travaux en français237 207→