Influence of Monitoring Strategy on Assessment of Ablation Success and Postablation Atrial Fibrillation Burden Assessment: Implications for Practice and Clinical Trial Design
Notice bibliographique
Résumé
Background: Various noninvasive intermittent rhythm monitoring strategies have been used to assess arrhythmia recurrences in trials evaluating pharmacological and invasive therapeutic interventions for atrial fibrillation (AF). We determined whether a frequency and duration of noninvasive rhythm monitoring could be identified that accurately detects arrhythmia recurrences and approximates the AF burden derived from continuous monitoring using an implantable cardiac monitor (ICM). Methods: The rhythm history of 346 patients enrolled in the CIRCA-DOSE trial (Cryoballoon Versus Contact-Force Irrigated Radiofrequency Catheter Ablation) was reconstructed. Using computer simulations, we evaluated event-free survival, sensitivity, negative predictive value, and AF burden of a range of noninvasive monitoring strategies, including those used in contemporary AF ablation trials. Results: A total of 126 290 monitoring days were included in the analysis. At 12 months, 164 patients experienced atrial arrhythmia recurrence as documented by the ICM (1-year event-free survival, 52.6%). Most noninvasive monitoring strategies used in AF ablation trials had poor sensitivity for detecting arrhythmia recurrence. Sensitivity increased with the intensity of monitoring, with serial (3) short-duration monitors (24-/48-hour ECG monitors) missing a substantial proportion of recurrences (sensitivity, 15.8% [95% CI, 8.9%–20.7%] and 24.5% [95% CI, 16.2%–30.6%], respectively). Serial (3) longer-term monitors (14-day ECG monitors) more closely approximated the gold standard ICM (sensitivity, 64.6% [95% CI, 53.6%–74.3%]). AF burden derived from short-duration monitors significantly overestimated the true AF burden in patients with recurrences. Increasing monitoring duration resulted in improved correlation and concordance between noninvasive estimates of the invasive AF burden ( R 2 = 0.85 and interclass correlation coefficient = 0.91 for serial [3] 14-day ECG monitors versus ICM). Conclusions: The observed rate of postablation atrial tachyarrhythmia recurrence is highly dependent on the arrhythmia monitoring strategy employed. Between-trial discrepancies in outcomes may reflect different monitoring protocols. On the basis of measures of agreement, serial long-term (7–14 day) intermittent monitors accumulating at least 28 days of annual monitoring provide estimates of AF burden comparable with ICM. However, ICMs outperform intermittent monitoring for arrhythmia detection, and should be considered the gold standard for clinical trials. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT01913522.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».