Computation of Surge Voltage in Transmission Tower Located Above Frequency-Dependent Soil
Notice bibliographique
Résumé
The purpose of this paper is to investigate the influence of frequency-dependent soils with variable soil content on the transient voltages at transmission towers. First, a comparative analysis between the impedance of tower-footing grounding rods buried in frequency-independent and frequency-dependent soils is carried. Then, the performance of ground potential rise (GPR) subjected to two types of lightning currents (first and subsequent return strokes) is studied. In a second part, these grounding rods are connected into a single-circuit transmission tower where the admittance of the structure located on frequency-independent and frequency-dependent soil is computed. The surge voltages generated by the two lightning currents are studied for these two types of soil. The frequency-domain responses are computed using the numerical method of Moments based on Electric Field Integral Equations in a frequency range from 100 Hz up to 10 MHz. Numerical results demonstrate that the frequency dependency of soil electrical parameters results in a modification of the rod impedance, especially at high frequencies. As a consequence, when the frequency-dependent soil is considered, a reduction at the transient voltage peaks is obtained compared with those calculated for a frequency-independent soil. This reduction is more pronounced when the transmission tower is located on the soil of high resistivity and subjected to a subsequent return stroke due to its higher energy at the high frequencies.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».