Computation of Surge Voltage in Transmission Tower Located Above Frequency-Dependent Soil
Notice bibliographique
Résumé
The purpose of this paper is to investigate the influence of frequency-dependent soils with variable soil content on the transient voltages at transmission towers. First, a comparative analysis between the impedance of tower-footing grounding rods buried in frequency-independent and frequency-dependent soils is carried. Then, the performance of ground potential rise (GPR) subjected to two types of lightning currents (first and subsequent return strokes) is studied. In a second part, these grounding rods are connected into a single-circuit transmission tower where the admittance of the structure located on frequency-independent and frequency-dependent soil is computed. The surge voltages generated by the two lightning currents are studied for these two types of soil. The frequency-domain responses are computed using the numerical method of Moments based on Electric Field Integral Equations in a frequency range from 100 Hz up to 10 MHz. Numerical results demonstrate that the frequency dependency of soil electrical parameters results in a modification of the rod impedance, especially at high frequencies. As a consequence, when the frequency-dependent soil is considered, a reduction at the transient voltage peaks is obtained compared with those calculated for a frequency-independent soil. This reduction is more pronounced when the transmission tower is located on the soil of high resistivity and subjected to a subsequent return stroke due to its higher energy at the high frequencies.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,001 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».