Usability Testing and Technology Acceptance of an mHealth App at the Point of Care During Simulated Pediatric In- and Out-of-Hospital Cardiopulmonary Resuscitations: Study Nested Within 2 Multicenter Randomized Controlled Trials
Notice bibliographique
Résumé
BACKGROUND: Mobile apps are increasingly being used in various domains of medicine. Few are evidence-based, and their benefits can only be achieved if end users intend to adopt and use them. To date, only a small fraction of mobile apps have published data on their field usability and end user acceptance results, especially in emergency medicine. OBJECTIVE: This study aims to determine the usability and acceptance of an evidence-based mobile app while safely preparing emergency drugs at the point of care during pediatric in- and out-of-hospital cardiopulmonary resuscitations by frontline caregivers. METHODS: In 2 multicenter randomized controlled parent trials conducted at 6 pediatric emergency departments from March 1 to December 31, 2017, and 14 emergency medical services from September 3, 2019, to January 21, 2020, the usability and technology acceptance of the PedAMINES (Pediatric Accurate Medication in Emergency Situations) app were evaluated among skilled pediatric emergency nurses and advanced paramedics when preparing continuous infusions of vasoactive drugs and direct intravenous emergency drugs at pediatric dosages during standardized, simulation-based, pediatric in- and out-of-hospital cardiac arrest scenarios, respectively. Usability was measured using the 10-item System Usability Scale. A 26-item technology acceptance self-administered survey (5-point Likert-type scales), adapted from the Unified Theory of Acceptance and Use of Technology model, was used to measure app acceptance and intention to use. RESULTS: All 100% (128/128) of nurses (crossover trial) and 49.3% (74/150) of paramedics (parallel trial) were assigned to the mobile app. Mean total scores on the System Usability Scale were excellent and reached 89.5 (SD 8.8; 95% CI 88.0-91.1) for nurses and 89.7 (SD 8.7; 95% CI 87.7-91.7) for paramedics. Acceptance of the technology was very good and rated on average >4.5/5 for 5 of the 8 independent constructs evaluated. Only the image construct scored between 3.2 and 3.5 by both participant populations. CONCLUSIONS: The results provide evidence that dedicated mobile apps can be easy to use and highly accepted at the point of care during in- and out-of-hospital cardiopulmonary resuscitations by frontline emergency caregivers. These findings can contribute to the implementation and valorization of studies aimed at evaluating the usability and acceptance of mobile apps in the field by caregivers, even in critical situations. TRIAL REGISTRATION: ClinicalTrials.gov NCT03021122; https://clinicaltrials.gov/ct2/show/NCT03021122. ClinicalTrials.gov NCT03921346; https://clinicaltrials.gov/ct2/show/NCT03921346. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): RR2-10.1186/s13063-019-3726-4.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,007 | 0,006 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,002 | 0,000 |
| Bibliométrie | 0,000 | 0,001 |
| Études des sciences et des technologies | 0,001 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».