An Active Protection Scheme for Microgrids Based on the Harmonic Injection
Notice bibliographique
Résumé
Inverter Interfaced Distributed Generation brings major challenges to the protection of microgrids, the traditional passive fault observation that does not use IIDG controllability, and the protection scheme based on the premise that the fault and non-fault characteristics are significantly different are no longer applicable. This paper proposes an active protection scheme for microgrid based on harmonic energy injection. The IIDG interface electrical signals are used for fault detection. In case of fault, the IIDG inverter started the harmonic energy injection function based on equivalent impedance modulation. The adjacent IIDG injected different frequencies’ harmonic energy. The closer the fault point was to IIDG, the greater the harmonic energy injected. The scheme collects the fault harmonic current in the relay, and sets the protection criterion based on the ratio of the detected harmonic currents of different IIDGs. The minimum range of fault clearing is realized by blocking logic. A harmonic current ratio relay is designed for the protection scheme. The proposed active protection scheme was suitable for microgrids with multiple IIDGs, and can meet both connected and island operation mode. A benchmark radial system practically under use in Canada was established in PSCAD/EMTDC, and the effectiveness of the scheme under different fault conditions was verified through simulation research.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».