Validation of spine SBRT using a 3D printed Anthropomorphic phantom
Notice bibliographique
Résumé
Abstract A segment of a spine was 3D-printed based on real patient anatomy, using metal-doped high density plastic to radiographically mimic bone. This spine was submerged in a water tank to create an anthropomorphic phantom. The spine print incorporated a slot for Gafchromic EBT3 film dosimeters and fiducials for alignment of measured and calculated dose distributions. Spine SBRT treatment plans were generated for both 6 MV and 10FFF energies based on oncologist-drawn contours transferred from real anatomy. Plans were delivered under image guidance using our clinical procedures, to evaluate the dosimetric accuracy of our planning system in high density inhomogeneities and the geometric accuracy of delivery. Results show that the Acuros XB algorithm (dose-to-water) agrees well with film measurements throughout the measured region, including within the bone substitute material. Alignment of the steep dose gradients in planned and measured doses was within 0.5 mm in the ANT-POST direction and within 0.9 mm in the SUP-INF direction, both within machine tolerances. Our results give us confidence in our ability to plan and accurately deliver spinal SBRT treatments.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».