MétaCan
Menu
Retour à la cohorte
Enregistrement W4207062922 · doi:10.14444/8146

Durability of Endoscopes Used During Routine Lumbar Endoscopy: An Analysis of Use Patterns, Common Failure Modes, Impact on Patient Care, and Contingency Plans

2021· article· en· W4207062922 sur OpenAlexaff
Kai‐Uwe Lewandrowski, Friedrich Tieber, Stefan Hellinger, Paulo Sérgio Teixeira de Carvalho, Max Rogério Freitas Ramos, André Luiz Calderaro, Thiago Soares dos Santos, Jorge Felipe Ramírez León, Marlon Sudário de Lima e Silva, Girish Datar, Jin‐Sung Kim, Hyeun Sung Kim, Anthony T. Yeung

Notice bibliographique

RevueThe International Journal of Spine Surgery · 2021
Typearticle
Langueen
DomaineMedicine
ThématiqueSpine and Intervertebral Disc Pathology
Établissements canadiensRegina General Hospital
Organismes subventionnairesnon disponible
Mots-clésMedicineEndoscopyDecompressionEndoscopeLumbar spinal stenosisSurgeryLumbarGeneral surgery

Résumé

récupéré en direct d'OpenAlex

BACKGROUND: Successful implementation of endoscopic spinal surgery programs hinges on reliable performance and case cost similar to traditional decompression surgeries of the lumbar spine. MATERIALS AND METHODS: To improve the statistical power of studying the durability of endoscopes with routine lumbar endoscopy, the authors performed a retrospective survey study among endoscopic spine surgeons by email and chat groups on social media networks WhatsApp and WeChat. Descriptive and correlative statistics were done on the surgeon's responses recorded in multiple-choice questions. Surgeons were asked about their clinical experience with spinal endoscopy, training background, the types of lumbar endoscopic decompression they perform by approach, their preferred decompression instruments, and their experience with endoscopic equipment failure. RESULTS: A total of 485 surgeons responded, of whom 85 submitted a valid survey recording, rendering a completion rate of 27.1%. These 85 respondents reported a case volume of 12,650 lumbar endoscopies within the past year and, to date, had performed a total of 120,150 spinal endoscopies over their collective career years. The majority of respondents performed endoscopic surgery for herniated disc (65.9%) vs spinal stenosis (34.1%) in a hospital setting, preferentially employing the transforaminal (76.5%), interlaminar (51.8%), and unilateral biportal endoscopic (UBE; 15.3%) approach technique. The most commonly used endoscopic spine systems were Wolf/Riwo Spine (38.8%), Joimax (36.5%), Storz (24.7%), unspecified Chinese brand (22.4%), Maxmore (15.3%), Spinendos (12.9%), Elliquence (10.6%), unspecified Korean brand (7.1%), and asap Endosystems GmbH (2.4%). The most frequent failure mode of the endoscope reported by survey respondents was a blurry image (71.8%), followed by the loss of focus (21.2%), the loss of illumination of the surgical site (18.8%), and the failure of the irrigation/suction system integrated into the endoscope (4.7%). Most respondents thought they had problems with the lens (67.1%), the fiberglass light conductor (23.5%), the prism (16.5%), or the rod system (4.7%). Motorized high-speed power burrs and hand reamers and trephines were the reported favorite decompression tools that were presumably associated with the endoscope's failure. The majority of respondents (49.5%) performed up to 50 endoscopies before the endoscope had to be either exchanged or repaired. Another 15.3% of respondents reported their endoscope lasted between 101 and 200 cases and only 12.9% reported more than 300 cases. Besides abuse during surgery (25.9%), bad handling by staff was the most common suspected reason (45.9%), followed by the wrong sterilization technique (21.2%). Some 23.5% of respondents noted that the endoscope failed during their surgery. In that case, 66.3% asked for a replacement endoscope, and 36.1% completed the surgery with the broken endoscope. However, 10.8% stopped and another 6% of respondents woke the patient up and rescheduled the surgery to complete the decompression at another time. CONCLUSIONS: Spinal endoscopes used during routine lumbar decompression surgeries for herniated disc and spinal stenosis have an estimated life cycle between 50 and 100 surgeries. Abusive use by surgeons, mishandling by staff, and deviation for prescribed cleaning and sterilization protocols may substantially shorten the life cycle. Contingency protocols should be in place to readily replace a broken spinal endoscope during surgery. More comprehensive implementation of endoscopic spine surgery techniques will hinge on technology advancements to make these hightech surgical instruments more resistant to the stress of daily use and abuse of expanded clinical indications' for surgery. The regulatory burden on endoscope makers is likely to increase, calling for increased reimbursement for facilities to cover the added expense for capital equipment purchase, disposables, and the endoscopic spine surgery program's maintenance. LEVEL OF EVIDENCE: 3. CLINICAL RELEVANCE: End user surgeon survey study.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction machine sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.

score de la tête « metaresearch » (Codex)0,004
score de la tête « metaresearch » (Gemma)0,015
Version: metacan-v3-hybrid-931329e0061cStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Observationnel · Signal consensuel: Observationnel
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,004
Score d'incertitude au seuil0,019

Scores du classifieur distillé par catégorie (deux têtes)

CatégorieCodexGemma
Métarecherche0,0040,015
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0000,001
Bibliométrie0,0020,002
Études des sciences et des technologies0,0000,000
Communication savante0,0010,001
Science ouverte0,0000,001
Intégrité de la recherche0,0000,000
Charge utile insuffisante (le modèle a refusé de juger)0,0010,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,023
Tête enseignante GPT0,309
Écart entre enseignants0,286 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeObservationnel
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations10
Publié2021
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueThe International Journal of Spine SurgeryMême sujetSpine and Intervertebral Disc PathologyTravaux en français237 207