Feasibility of dual-energy CBCT by spectral filtration of a dual-focus CNT x-ray source
Pourquoi ce travail est dans la base
Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.
Notice bibliographique
Résumé
Cone beam computed tomography (CBCT) is now widely used in dentistry and growing areas of medical imaging. The presence of strong metal artifacts is however a major concern of using CBCT especially in dentistry due to the presence of highly attenuating dental restorations, fixed appliances, and implants. Virtual monoenergetic images (VMIs) synthesized from dual energy CT (DECT) datasets are known to reduce metal artifacts. Although several techniques exist for DECT imaging, they in general come with significantly increased equipment cost and not available in dental clinics. The objectives of this study were to investigate the feasibility of developing a low-cost dual energy CBCT (DE-CBCT) by retrofitting a regular CBCT scanner with a carbon nanotube (CNT) x-ray source with dual focal spots and corresponding low-energy (LE) and high-energy (HE) spectral filters. A testbed with a CNT field emission x-ray source (NuRay Technology, Chang Zhou, China), a flat panel detector (Teledyne, Waterloo, Canada), and a rotating object stage was used for this feasibility study. Two distinct polychromatic x-ray spectra with the mean photon energies of 66.7keV and 86.3keV were produced at a fixed 120kVp x-ray tube voltage by using Al+Au and Al+Sn foils as the respective LE and HE filters attached to the exist window of the x-ray source. The HE filter attenuated the x-ray photons more than the LE filter. The calculated post-object air kerma rate of the HE beam was 31.7% of the LE beam. An anthropomorphic head phantom (RANDO, Nuclear Associates, Hicksville, NY) with metal beads was imaged using the testbed and the images were reconstructed using an iterative volumetric CT reconstruction algorithm. The VMIs were synthesized using an image-domain basis materials decomposition method with energy ranging from 30 to 150keV. The results were compared to the reconstructed images from a single energy clinical dental CBCT scanner (CS9300, Carestream Dental, Atlanta, GA). A significant reduction of the metal artifacts was observed in the VMI images synthesized at high energies compared to those from the same object imaged by the clinical dental CBCT scanner. The ability of the CNT x-ray source to generate the output needed to compensate the reduction of photon flux due to attenuation from the spectral filters and to maintain the CT imaging time was evaluated. The results demonstrated the feasibility of DE-CBCT imaging using the proposed approach. Metal artifact reduction was achieved in VMIs synthesized. The x-ray output needed for the proposed DE-CBCT can be generated by a fixed-anode CNT x-ray source.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle