Guidelines for the Appropriate Use of Bedside General and Cardiac Ultrasonography in the Evaluation of Critically Ill Patients—Part II: Cardiac Ultrasonography
Pourquoi ce travail est dans la base
Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.
Notice bibliographique
Résumé
Objective: To establish evidence-based guidelines for the use of bedside cardiac ultrasound, echocardiography, in the ICU and equivalent care sites. Methods: Grading of Recommendations, Assessment, Development and Evaluation system was used to rank the “levels” of quality of evidence into high (A), moderate (B), or low (C) and to determine the “strength” of recommendations as either strong (strength class 1) or conditional/weak (strength class 2), thus generating six “grades” of recommendations (1A–1B–1C–2A–2B–2C). Grading of Recommendations, Assessment, Development and Evaluation was used for all questions with clinically relevant outcomes. RAND Appropriateness Method, incorporating the modified Delphi technique, was used in formulating recommendations related to terminology or definitions or in those based purely on expert consensus. The process was conducted by teleconference and electronic-based discussion, following clear rules for establishing consensus and agreement/disagreement. Individual panel members provided full disclosure and were judged to be free of any commercial bias. Results: Forty-five statements were considered. Among these statements, six did not achieve agreement based on RAND appropriateness method rules (majority of at least 70%). Fifteen statements were approved as conditional recommendations (strength class 2). The rest (24 statements) were approved as strong recommendations (strength class 1). Each recommendation was also linked to its level of quality of evidence and the required level of echo expertise of the intensivist. Key recommendations, listed by category, included the use of cardiac ultrasonography to assess preload responsiveness in mechanically ventilated (1B) patients, left ventricular (LV) systolic (1C) and diastolic (2C) function, acute cor pulmonale (ACP) (1C), pulmonary hypertension (1B), symptomatic pulmonary embolism (PE) (1C), right ventricular (RV) infarct (1C), the efficacy of fluid resuscitation (1C) and inotropic therapy (2C), presence of RV dysfunction (2C) in septic shock, the reason for cardiac arrest to assist in cardiopulmonary resuscitation (1B–2C depending on rhythm), status in acute coronary syndromes (ACS) (1C), the presence of pericardial effusion (1C), cardiac tamponade (1B), valvular dysfunction (1C), endocarditis in native (2C) or mechanical valves (1B), great vessel disease and injury (2C), penetrating chest trauma (1C) and for use of contrast (1B–2C depending on indication). Finally, several recommendations were made regarding the use of bedside cardiac ultrasound in pediatric patients ranging from 1B for preload responsiveness to no recommendation for RV dysfunction. Conclusions: There was strong agreement among a large cohort of international experts regarding several class 1 recommendations for the use of bedside cardiac ultrasound, echocardiography, in the ICU. Evidence-based recommendations regarding the appropriate use of this technology are a step toward improving patient outcomes in relevant patients and guiding appropriate integration of ultrasound into critical care practice.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,003 | 0,071 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,002 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle