MétaCan
Menu
Retour à la cohorte
Enregistrement W4211073013 · doi:10.1002/14651858.cd011415.pub2

Mini-Cog for the diagnosis of Alzheimer’s disease dementia and other dementias within a primary care setting

2018· review· en· W4211073013 sur OpenAlexafffund
Dallas Seitz, Calvin Chan, Hailey T. Newton, Sudeep S. Gill, Nathan Herrmann, Nadja Smailagic, Vasilis Nikolaou, Bruce Fage

Notice bibliographique

RevueCochrane Database of Systematic Reviews · 2018
Typereview
Langueen
DomaineMedicine
ThématiqueDementia and Cognitive Impairment Research
Établissements canadiensUniversity of TorontoSunnybrook Health Science CentreQueen's University
Organismes subventionnairesCanadian Institutes of Health ResearchEvidence Synthesis ProgrammeNational Institute for Health and Care Research
Mots-clésDementiaMedicineMEDLINEDiseaseCognitive testCognitionAlzheimer's diseasePsychiatryPathology

Résumé

récupéré en direct d'OpenAlex

BACKGROUND: Alzheimer's disease and other forms of dementia are becoming increasingly common with the aging of most populations. The majority of individuals with dementia will first present for care and assessment in primary care settings. There is a need for brief dementia screening instruments that can accurately diagnose dementia in primary care settings. The Mini-Cog is a brief, cognitive screening test that is frequently used to evaluate cognition in older adults in various settings. OBJECTIVES: To determine the diagnostic accuracy of the Mini-Cog for diagnosing Alzheimer's disease dementia and related dementias in a primary care setting. SEARCH METHODS: We searched the Cochrane Dementia and Cognitive Improvement Register of Diagnostic Test Accuracy Studies, MEDLINE, Embase and four other databases, initially to September 2012. Since then, four updates to the search were performed using the same search methods, and the most recent was January 2017. We used citation tracking (using the databases' 'related articles' feature, where available) as an additional search method and contacted authors of eligible studies for unpublished data. SELECTION CRITERIA: We only included studies that evaluated the Mini-Cog as an index test for the diagnosis of Alzheimer's disease dementia or related forms of dementia when compared to a reference standard using validated criteria for dementia. We only included studies that were conducted in primary care populations. DATA COLLECTION AND ANALYSIS: We extracted and described information on the characteristics of the study participants and study setting. Using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) criteria we evaluated the quality of studies, and we assessed risk of bias and applicability of each study for each domain in QUADAS-2. Two review authors independently extracted information on the true positives, true negatives, false positives, and false negatives and entered the data into Review Manager 5 (RevMan 5). We then used RevMan 5 to determine the sensitivity, specificity, and 95% confidence intervals. We summarized the sensitivity and specificity of the Mini-Cog in the individual studies in forest plots and also plotted them in a receiver operating characteristic plot. We also created a 'Risk of bias' and applicability concerns graph to summarize information related to the quality of included studies. MAIN RESULTS: There were a total of four studies that met our inclusion criteria, including a total of 1517 total participants. The sensitivity of the Mini-Cog varied between 0.76 to 1.00 in studies while the specificity varied between 0.27 to 0.85. The included studies displayed significant heterogeneity in both methodologies and clinical populations, which did not allow for a meta-analysis to be completed. Only one study (Holsinger 2012) was found to be at low risk of bias on all methodological domains. The results of this study reported that the sensitivity of the Mini-Cog was 0.76 and the specificity was 0.73. We found the quality of all other included studies to be low due to a high risk of bias with methodological limitations primarily in their selection of participants. AUTHORS' CONCLUSIONS: There is a limited number of studies evaluating the accuracy of the Mini-Cog for the diagnosis of dementia in primary care settings. Given the small number of studies, the wide range in estimates of the accuracy of the Mini-Cog, and methodological limitations identified in most of the studies, at the present time there is insufficient evidence to recommend that the Mini-Cog be used as a screening test for dementia in primary care. Further studies are required to determine the accuracy of Mini-Cog in primary care and whether this tool has sufficient diagnostic test accuracy to be useful as a screening test in this setting.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,006
score de la tête « metaresearch » (Gemma)0,002
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesMéta-épidémiologie (sens strict)
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Revue systématique · Signal consensuel: Revue systématique
GenreSignal candidat: Synthèse · Signal consensuel: Synthèse
Score de désaccord entre enseignants0,176
Score d'incertitude au seuil1,000

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0060,002
Méta-épidémiologie (sens strict)0,0010,000
Méta-épidémiologie (sens large)0,0050,001
Bibliométrie0,0000,000
Études des sciences et des technologies0,0000,000
Communication savante0,0000,000
Science ouverte0,0000,000
Intégrité de la recherche0,0000,000
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,142
Tête enseignante GPT0,418
Écart entre enseignants0,277 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.

Devis d'étudeRevue systématique
Domainenon disponible
GenreSynthèse

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations70
Publié2018
Routes d'admission2
Résumé présentoui

Explorer davantage

Même revueCochrane Database of Systematic ReviewsMême sujetDementia and Cognitive Impairment ResearchTravaux en français237 207