Implementation of a blood bank generated tube for second blood group determination: Challenges, yield, and cost
Notice bibliographique
Résumé
BACKGROUND: The second blood group determination or group check sample is a process of verifying the ABO group with a second blood sample prior to transfusion. It has been used to detect errors related to wrong blood in tube (WBIT) events and reduce the risk of ABO-incompatible transfusions. To prevent the clinical team from collecting the group check sample at the same time as the first sample, a tan top tube only available from the blood bank was introduced for second blood group determinations if drawn within 24 h of the first group and screen. STUDY DESIGN AND METHODS: This is a retrospective study analyzing data from 2005 to 2020 before and after the implementation of the blood bank supplied tan top tube for group check. The number of WBIT events, transfusion delays, and health care costs were determined. RESULTS: The number of WBIT events remained unchanged throughout the time period. No delays in transfusion or procedure were reported due to the tan top tube group check. There was no increase in group O transfusions over time. In comparison to using an ethylenediaminetetraacetic acid (EDTA) tube, the tan top tube was estimated to add an extra yearly cost of $790.79 Canadian dollars. CONCLUSION: Second blood group determination using the blood bank supplied tan top tube did not increase the number of WBIT events detected but ensured an independent sample draw. A minimal incremental cost of implementing the tan top tube was noted with no delay in transfusions or procedures.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,002 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification