Investigation of position linearity in position-sensitive microstrip amorphous selenium-based detector
Notice bibliographique
Résumé
A high spatial resolution and cost-effective amorphous selenium multi-layer detector architecture was previously proposed for high-energy applications including single-photon emission computed tomography (SPECT). To overcome the complexity of reading out signal from the multi-layer detector, we propose a resistive microstrip detector readout using charge division. The charge induced on the readout electrode undergoes charge division along the electrode and is proportional to the physical location of absorbed photons, enabling position sensitivity. A 1 mm collimated blue LED is employed to illuminate the electrode, which has a resistance of 242 kΩ. To improve the linearity of the position sensing, the microstrips were deposited underneath a-Se in order to move bonding pads far away from the active area. A low deposition temperature evaporated Cs-doped and As-stabilized a-Se layer is used as a hole blocking layer to ensure that the resistivity of microstrips is not affected and to prevent crystallization of the temperature sensitive a-Se layer. The detector structure was fabricated on a flexible substrate that can potentially be incorporated, in the future, into a curved detector structure for large area SPECT systems. The results presented demonstrate that the detected position is linearly proportional to the location of absorbed photons with a spatial resolution of 1 mm.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,001 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,001 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».